Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To describe the transvenous application of intracardiac echocardiography (ICE) for guidance during endovascular aortic repair (EVAR).
Materials And Methods: Eight patients with an infrarenal abdominal aortic aneurysm (AAA) and chronic renal failure were determined suitable for EVAR. The procedure was performed by deploying the transcaval and transiliac vein guidance of an ICE catheter to reduce the dosage of iodinated contrast medium. Multiple guidance parameters were assessed. The present study describes the EVAR procedure and postprocedure transabdominal ultrasound (US) follow-up results at 3-4 months.
Results: The eight procedures were completed by using transvenous ICE guidance. No contrast medium was used in five patients, and 3-20 mL of isoosmolar contrast medium was administered in the other three. No endoleaks were detected by ICE immediately after stent deployment. One patient who had a single functioning kidney developed renal failure that was attributed to manipulation-related cholesterol embolization. That patient became dependent on dialysis and died 3.5 months after the procedure. No endoleaks were detected at 3-4-month US follow-up in the other seven patients.
Conclusions: Transvenous ICE guidance is a promising method to reduce the dosage of iodinated contrast medium in patients with renal dysfunction undergoing EVAR. A prospective trial comparing this modality versus digital subtraction angiography guidance with iodinated contrast medium in terms of safety, accuracy, and long-term efficacy is recommended.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvir.2013.12.561 | DOI Listing |