A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Baseline elevated Lp-PLA2 is associated with increased risk for re-stenosis after stent placement. | LitMetric

AI Article Synopsis

  • Lipoprotein associated phospholipase A2 (Lp-PLA2) is a potential biomarker for predicting cardiovascular risk, specifically concerning re-stenosis after stent placement.
  • A study involving 326 participants found a significant difference in Lp-PLA2 levels between groups, with the elevated group showing a higher incidence of tri-vessel stenosis and a marginally increased rate of re-stenosis after one year (8.5% vs. 4.6%).
  • Despite comparable clinical outcomes overall, Lp-PLA2 levels emerged as an independent predictor for re-stenosis risk, suggesting that measuring Lp-PLA2 could help identify patients at higher risk post-stent

Article Abstract

Background: Lipoprotein associated phospholipase A2 (Lp-PLA2) is a novel biomarker for cardiovascular risk prediction. Whether increased Lp-PLA2 level is associated with re-stenosis after stent-placement is unclear.

Methods: Totally 326 participants eligible for stent-placement were enrolled and divided into two groups according to baseline Lp-PLA2 levels (named normal and elevated groups). Baseline characteristics and clinical outcomes were compared between normal and elevated groups. The relationships between Lp-PLA2 and other risk factors with re-stenosis were evaluated.

Results: Only the between-group difference of Lp-PLA2 was significant (123.2 ± 33.6 ng/mL vs 336.8 ± 85.4 ng/mL, P < 0.001) while other demographic and clinical characteristics between these two groups were comparable. Approximately 55.1% and 58.5% of participants in normal and elevated groups presented with acute coronary syndrome, and the percentage of tri-vessels stenoses was significantly higher in elevated group (40.8% vs 32.1%, P = 0.016). Nearly 96.0% and 94.0% of participants in normal and elevated Lp-PLA2 groups were placed with drug-eluting stents, and the others were with bare-metal stents. After 1 year's follow-up, the incidence of clinical end-points was comparable (13.3% vs 15.4%, P = 0.172). Nevertheless, the incidence of re-stenosis was marginally higher in elevated Lp-PLA2 group (8.5% versus 4.6%, P = 0.047). With multivariate analysis, after adjustment for other risk factors, Lp-PLA2 remained an independent predictor for re-stenosis with a hazard ratio of 1.140. No synergistic effect between Lp-PLA2 and other risk factors for re-stenosis was found.

Conclusion: Increased Lp-PLA2 level is associated with an increased risk of re-stenosis. Lp-PLA2 assessment may be useful in predicting subjects who are at increased risk for re-stenosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3975936PMC
http://dx.doi.org/10.1186/1476-511X-13-41DOI Listing

Publication Analysis

Top Keywords

groups baseline
8
normal elevated
8
elevated groups
8
lp-pla2
6
baseline elevated
4
elevated lp-pla2
4
lp-pla2 associated
4
associated increased
4
increased risk
4
risk re-stenosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!