A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of automatic scanning of microscope slides in recovering rare cellular events: application for detection of fetal cells in maternal blood. | LitMetric

Objective: Detection of rare fetal cells (FCs) in the maternal circulation could be used for non-invasive prenatal diagnosis. Considering that FCs in maternal blood are present in extremely low frequency, manual scanning is cumbersome, time-consuming, and unsuitable for clinical applications. As an alternative, we optimized a custom-made classifier for automatic detection of FCs.

Methods: Using MetaSystems' automated platform, we developed a robust detection algorithm and validated its efficiency on retrieval of rare XY cells in a pure population of XX cells. Slides were scanned for presence of predefined XY cells after fluorescence in situ hybridization (FISH) and primed in situ labeling (PRINS). Retrieval of FCs was also performed on samples from maternal blood.

Results: The efficiency of detection of rare XY cells was 88% using FISH (117/133) in comparison with 78% (53/68) with PRINS. FC frequencies per 1 mL of maternal blood ranged from 3 to 6 FCs in normal pregnancies versus 13 to 21 FCs in Down syndrome pregnancies.

Conclusion: Automatic scanning was more efficient and consistent than manual scanning for detection of rare FCs and required considerably less operator time. Automatic scanning using FISH is more sensitive than that using PRINS. The study validates automatic scanning retrieval of FCs from maternal blood.

Download full-text PDF

Source
http://dx.doi.org/10.1002/pd.4345DOI Listing

Publication Analysis

Top Keywords

automatic scanning
16
maternal blood
16
detection rare
12
fcs maternal
12
fetal cells
8
manual scanning
8
rare cells
8
retrieval fcs
8
fcs
7
scanning
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!