Cheek drooping in 2 patients with maxillary fractures after rigid fixation with bioabsorbable mesh.

J Craniofac Surg

* Department of Plastic and Reconstructive Surgery, Bundang CHA Medical Center, CHA University, Seongnam; and †Department of Plastic and Reconstructive Surgery, School of Medicine, Konkuk University, Seoul, South Korea.

Published: March 2014

Bioabsorbable plate-screw systems are commonly used for the internal fixation of facial bone fractures. The anterior maxilla has a unique curved shape, and fractured bony fragments tend to be small and fragile; therefore, more effective rigid fixation can be achieved using a molded bioabsorbable mesh rather than a bioabsorbable plate. Herein, we describe 2 patients with cheek drooping after a rigid fixation of comminuted maxillary fracture using bioabsorbable meshes and screws.The postoperative courses were uneventful, but both showed soft tissue bulging in the cheek area of the operation site for 12 to 13 months after the operation. No other symptom or sign related to inflammation or foreign body reaction was noted.In comminuted maxillary fractures, bone fragments are more conveniently fixed with a 1-piece molded bioabsorbable mesh. However, it is believed that a single large mesh may interfere with adhesion between the maxillary surface and the overlying soft tissue. Therefore, we recommend using the least amount of mesh to fixate maxillary bone fragments.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000000697DOI Listing

Publication Analysis

Top Keywords

rigid fixation
12
bioabsorbable mesh
12
cheek drooping
8
maxillary fractures
8
mesh bioabsorbable
8
molded bioabsorbable
8
comminuted maxillary
8
soft tissue
8
bone fragments
8
bioabsorbable
6

Similar Publications

The aim of this study was to investigate the effect of the presence of the "cortex sign" (corticalization) in femoral diaphysis fractures determined by the dynamization of nails because of delayed union. The study included 12 patients with a closed transverse femoral fracture (AO 32a3) treated with dynamization (all the screws distal of the nail were removed) because of delayed healing and followed up for at least 2 years. These patients were evaluated for the presence of bone union, cortex-like sclerosis (corticalization) distal to the nail, and the distance of the corticalization from the joint during follow- up after dynamization.

View Article and Find Full Text PDF

Purpose: This study aims to compare the biomechanical performance of elastic and static suture-based cerclage systems to traditional screw constructs in the setting of modeled glenoid bony augmentation.

Methods: Biomechanical testing was conducted on polyurethane cellular foam blocks modeling a 20 % glenoid defect repaired with a coracoid graft. Constructs consisted of an elastic suture-based cerclage, static suture-based cerclage, and a two-screw construct.

View Article and Find Full Text PDF

Objectives: This study aims to analyze the biomechanics of three kinds of rigid internal fixation methods for condylar head fractures.

Methods: A three dimensional finite element model of the normal mandible was constructed. It was then used to prepare condylar head fracture finite element model and three kinds of rigid internal fixation finite element model (unilateral tension screw, bilateral tension screw, tension screw+titanium plate).

View Article and Find Full Text PDF

Background: Length unstable femoral shaft fractures in school-aged children usually demand surgical treatment, but the optimal choice remains controversial, especially in overweight adolescents. This study aimed to compare the clinical results of locking compression plates (LCP) and elastic stable intramedullary nails (ESIN) combined with temporary external fixator (TEF) in school-aged children weighing over 50 kg.

Methods: Between January 2010 and January 2018, children over 50 kg with length unstable femoral shaft fracture treated with ESIN & EF in the authors' institute were included in this study.

View Article and Find Full Text PDF

[Treatment of geriatric odontoid fractures].

Unfallchirurgie (Heidelb)

February 2025

Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Freiburg, Hugstetter Straße 55, 79106, Freiburg, Deutschland.

The treatment of odontoid fractures in geriatric patients, particularly type II fractures, remains controversial. In biologically young patients, studies suggest advantages of surgical treatment in terms of mortality; however, this advantage is not observed in geriatric patients. While the mortality appears to be higher after conservative treatment in patients aged 65-80 years, there are studies that have shown no differences in mortality for patients aged 80 years or older and even showed advantages of conservative treatment in this age group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!