Unlabelled: Some findings in standard electrocardiogram (ECG) may be associated with paroxysmal atrial fibrillation (AF). The aim of the study was to evaluate P wave duration and P wave dispersion (Pdysp) derived from 12-lead standard surface ECG in sinus rhythm in patients with history of AF in comparison to control subjects without AF and with premature ventricular ectopic beats (PVEB).
Material And Methods: The study group consisted of 20 patients (pts), 9M. 11F, mean age 47.6 +/- 5.5 years with paroxysmal AF. The control group consisted of 19 pts, 9M, 10F, mean age 46.7 +/- 4.7 years without history of AF with PVEB. All patients in both groups were treated with antiarrhythmic drugs. Left atrium dimensions (LA) in the transthoracic echocardiographic examinations (TTE) and maximal (P(max)), minimal (P(min)) wave duration and P(dysp) in a ECG recordings were analyzed. Pdysp was calculated as the difference between P(max) and P(min).
Results: ECG analysis showed statistically significant differences, study group vs control group in P wave duration and P(dysp). We found that in AF group P(max) and P(dysp) were significantly greater (125.5 vs. 114.5 ms, p < 0.005 and 59.5 vs 45.4 ms, p < 0.01, respectively). LA were significantly greater in AF group (43.7 vs 41.8 mm, p < 0.05). P(dysp) correlated significantly with P(mex) and LA.
Conclusions: In AF patients, P wave duration and P wave dispersion, in other words atrial depolarization/repolarization inhomogeneity, were increased. A significant positive correlation between P wave dispersion and both Pmax and left atrium size were found.
Download full-text PDF |
Source |
---|
Eur Stroke J
January 2025
Department of Neurology, University Hospital RWTH Aachen, Aachen, Germany.
Introduction: Distal arterial occlusions can cause measurable changes in the flow wave profile in proximal segments of the feeding artery. Our objective was to study the diagnostic accuracy of point-of-care ultrasound (POCUS) of the common carotid arteries (CCA) for detection of anterior circulation large vessel occlusion (ac-LVO) in patients with suspected stroke.
Patients And Methods: We conducted a prospective, single-center, observational study of adult patients with suspected stroke admitted in the emergency department.
Int J Cardiol Cardiovasc Risk Prev
March 2025
Department of Cardiology, National University Heart Centre Singapore, Singapore.
Introduction: The severity of mitral stenosis (MS) is commonly assessed using mitral valve area (MVA) measured with transthoracic echocardiography (TTE). The dimensionless index (DI) of mitral valve (MV) was recently studied in degenerative MS. We evaluated DI MV in rheumatic MS and studied its relationship with clinical outcomes.
View Article and Find Full Text PDFBroadband microwave signals with customized chirp shapes are highly captivating in practical applications. Compared with electronic technology, photonic solutions are superior in bandwidth but suffer from flexible and rapid manipulation of chirp shape or frequency. Here, we demonstrate a concept for generating broadband microwave signals with programmable chirp shapes.
View Article and Find Full Text PDFThe space-time wave packet (STWP) is a type of pulsed optical field, exhibiting distinctive characteristics, including the capacity to propagate without diffraction or dispersion and to have arbitrary group velocities. However, the intensity of the STWP is constrained by the low damage threshold of some indispensable optical elements like the spatial light modulator (SLM). While optical parametric amplification (OPA) has been proposed for amplifying STWPs, spatio-temporal (ST) characteristics of amplified STWPs remain significantly unexplored.
View Article and Find Full Text PDFDoc Ophthalmol
January 2025
Department of Ophthalmology and Visual Sciences, Research Institute of the McGill University Health Centre/Montreal Children's Hospital, 1001 Décarie Boulevard, Glen Site, Block E, Office #EM03238, Montréal, QC, H4A 3J1, Canada.
Purpose: Study the scotopic oscillatory potentials (OPs) in mice over a wide range of flash luminance levels using the Hilbert transform (HT) to extract new features of the high frequency components of the electroretinogram (ERG).
Methods: Scotopic ERGs [Intensity: - 6.3 to 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!