A new multisensor pacing device using respiratory rate (RR), stroke volume (SV), oxygen saturation (SO2), temperature (T), right atrial pressure (RAP), right ventricular pressure (RVP) and right ventricular dP/dt, has been developed. It consists of a 7F multisensor catheter and an external pacing unit. It allows simultaneous recording of the input signals and the corresponding data can be compared among the different parameters under identical conditions. Furthermore, several parameters can be combined in such a way as to form a new combination better suitable for rate responsive pacing. The response of each parameter to exercise was studied in 12 healthy volunteers (mean age: 28 years). Exercise testing was carried out using a bicycle ergometer, with workloads up to 200 W. The dynamic characteristics, response and sensitivity to changes of workloads of each parameter were analyzed and compared to one another. SO2 proved to be a quick responding parameter (less than 10 sec) with higher sensitivity in the low exercise range (less than 75 W), T, on the other hand, responded slowly (greater than 30 sec) to exercise changes and had the highest sensitivity in the exercise range beyond 75 W. RR displayed a slow response (greater than 30 sec) and an adequate sensitivity was only found in the upper exercise range (greater than 100 W). SV reacted rapidly to workload changes (less than 10 sec) but showed poor sensitivity at all exercise levels. RAP, RVP and dP/dt displayed quick responses and constantly good sensitivity throughout the workload range. Furthermore, respiratory rate was easily derived from the RAP curve. Special algorithms were developed for each parameter so that pacing rate would reproduce sinus rate behavior. We found that SO2 and all pressure parameter imitated sinus rate response quite well. When using parameter combinations, SO2 and T proved to be superior. Five patients (mean age 68 years) with third degree AV-block were stimulated temporarily using this system. Compared to fixed rate stimulation (VVI 70), exercise performance improved, using SO2 as the input parameter for rate response, by 25% to 50%.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.1988.tb06021.xDOI Listing

Publication Analysis

Top Keywords

respiratory rate
12
exercise range
12
rate
9
multisensor pacing
8
stroke volume
8
oxygen saturation
8
temperature atrial
8
atrial pressure
8
ventricular pressure
8
exercise
8

Similar Publications

Introduction: Coronavirus disease 2019 (COVID-19) is a life-threatening disease that was declared a pandemic in March 2020. Organ transplant recipients are vulnerable to infection and complications from COVID-19. The objective of this study was to investigate the rates of infection, mortality, and case-fatality ratios (CFR) in solid organ transplant recipients and patients on the waiting list for organ allocation in the period prior to the availability of specific vaccines.

View Article and Find Full Text PDF

Neutrophil-to-lymphocyte ratio and short-term mortality in patients having anti-MDA5-positive dermatomyositis with interstitial lung disease: a retrospective study.

BMC Pulm Med

January 2025

Department of Key Laboratory of Ningxia Stem Cell and Regenerative Medicine, Institute of Medical Sciences, Department of Pulmonary and Critical Care Medicine, General Hospital of Ningxia Medical University, Yinchuan, Ningxia, 750004, China.

Background: In this study, we aimed to explore the association between baseline and early changes in the neutrophil-to-lymphocyte ratio (NLR) and the 30-day mortality rate in patients having anti-melanoma differentiation-associated gene 5 (MDA5)-positive dermatomyositis with interstitial lung disease (DM-ILD).

Methods: Overall, 263 patients with anti-MDA5 DM-ILD from four centers in China were analyzed. Multivariate logistic regression analysis was used to evaluate the impact of baseline NLR on the 30-day mortality rate in patients with anti-MDA5-positive DM-ILD.

View Article and Find Full Text PDF

Background: The clinical manifestations and course of rheumatoid arthritis-associated interstitial lung disease (RA-ILD) exhibits considerable heterogeneity. In this study, we aimed to explore radiographic progression over a defined period, employing the Warrick score as a semi-quantitative measure in early RA-ILD, and to assess the associated risk factors for progression.

Methods: RA-ILD patients underwent consecutive Warrick scoring based on initial high-resolution computed tomography (HRCT) at diagnosis and the first follow-up.

View Article and Find Full Text PDF

Mechanical ventilation is the process through which breathing support is provided to patients who face inconvenience during respiration. During the pandemic, many people were suffering from lung disorders, which elevated the demand for mechanical ventilators. The handling of mechanical ventilators is to be done under the assistance of trained professionals and demands the selection of ideal parameters.

View Article and Find Full Text PDF

Objective: We aimed to develop a highly interpretable and effective, machine-learning based risk prediction algorithm to predict in-hospital mortality, intubation and adverse cardiovascular events in patients hospitalised with COVID-19 in Australia (AUS-COVID Score).

Materials And Methods: This prospective study across 21 hospitals included 1714 consecutive patients aged ≥ 18 in their index hospitalization with COVID-19. The dataset was separated into training (80%) and test sets (20%).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!