AI Article Synopsis

  • HES 130/0.4 is more effective than lactated Ringer solution in reducing the need for blood transfusions and postoperative infections during hip arthroplasty under spinal anesthesia.
  • The study involved 48 patients, with those receiving HES requiring transfusions in only 17% of cases compared to 46% in the Ringer group.
  • There were no significant differences in mortality, length of hospital stay, or other clinical complications, suggesting HES may be a safer option for fluid resuscitation in this context.

Article Abstract

Background And Objectives: Hydroxyethyl starch (HES) 130/0.4 is considered an effective plasma expander when compared to crystalloids. There is controversy around its superiority regarding hemodynamic optimization and about possible detrimental effects on coagulation. The aim of this study was to compare the effects of HES 130/0.4 to lactated Ringer solution during hip arthroplasty in adult patients under spinal anesthesia regarding intraoperative bleeding, hemodynamic parameters, coagulation profile, transfusion requirements and clinical outcomes.

Methods: In this randomized, controlled trial, 48 patients scheduled for hip arthroplasty with spinal anesthesia were randomized into two groups: 24 patients were allocated to receive a preload of 15 mL.kg(-1) of HES 130/0.4 and 24 patients received a preload of 30 mL.kg(-1) lactated Ringer solution before surgery. Hemodynamic measurements, hemoglobin concentrations, biochemical parameters and coagulation tests were evaluated in three periods during surgical procedure. Patients received medical follow-up during their hospital stay and up to postoperative 30 days. Primary outcome was the requirement of red blood cell transfusion between groups during hospital stay. Secondary outcome were hemodynamic parameters, length of hospital stay, mortality and occurrence of clinical postoperative complications.

Results: Red blood cell transfusion was required in 17% of patients in the HES group and in 46% in the Ringer group (p = .029). Postoperative infections were more frequently observed in the Ringer group (17%) compared to the HES group (0), p = .037. There were no significant differences between groups in mortality, hospital length of stay and clinical complications other than infection.

Conclusions: During hip arthroplasty, patients treated with hypervolemic hemodilution with hydroxyethyl starch 130/0.4 required less transfusion and presented lower infection rate compared to patients who received lactated Ringer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bjane.2012.03.002DOI Listing

Publication Analysis

Top Keywords

hip arthroplasty
16
lactated ringer
16
hydroxyethyl starch
12
starch 130/04
12
patients received
12
hospital stay
12
ringer solution
8
patients
8
spinal anesthesia
8
hemodynamic parameters
8