The dispersion curves for hollow multilayered cylinders are prerequisites in any practical guided waves application on such structures. The equations for homogeneous isotropic materials have been established more than 120 years ago. The difficulties in finding numerical solutions to analytic expressions remain considerable, especially if the materials are orthotropic visco-elastic as in the composites used for pipes in the last decades. Among other numerical techniques, the semi-analytical finite elements method has proven its capability of solving this problem. Two possibilities exist to model a finite elements eigenvalue problem: a two-dimensional cross-section model of the pipe or a radial segment model, intersecting the layers between the inner and the outer radius of the pipe. The last possibility is here adopted and distinct differential problems are deduced for longitudinal L(0,n), torsional T(0,n) and flexural F(m,n) modes. Eigenvalue problems are deduced for the three modes classes, offering explicit forms of each coefficient for the matrices used in an available general purpose finite elements code. Comparisons with existing solutions for pipes filled with non-linear viscoelastic fluid or visco-elastic coatings as well as for a fully orthotropic hollow cylinder are all proving the reliability and ease of use of this method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultras.2014.01.019 | DOI Listing |
Orthop Surg
January 2025
Department of Trauma and Orthopeadics, Peking University People's Hospital, Beijing, People's Republic of China.
Objective: Reverse obliquity intertrochanteric fracture is an unstable type of fracture. Current guidelines recommend intramedullary fixation, but there are still complications such as screw removal, hip varus, nail withdrawal, and nail fracture. The objective of this study was to use finite element analysis to compare the biomechanical properties of the novel proximal femoral bionic nail (PFBN), proximal femoral nail antirotation (PFNA), and combined compression interlocking intramedullary nail (InterTan) in the treatment of reverse obliquity intertrochanteric fractures (AO/OTA 31-A3.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Background: The spatial resolution of new, photon counting detector (PCD) CT scanners is limited by the size of the focal spot. Smaller, brighter focal spots would melt the tungsten focal track of a conventional X-ray source.
Purpose: To propose focal spot multiplexing (FSM), an architecture to improve the power of small focal spots and thereby enable higher resolution clinical PCD CT.
J Colloid Interface Sci
January 2025
School of Resources, Environment and Materials, Guangxi University, Nanning 530004, China. Electronic address:
The limited transport of oxygen at the solid-liquid interface and the poor charge separation efficiency of single catalyst significantly impedes the generation of reactive oxygen species (ROS), thereby weakening the application potential of photocatalytic technology in water pollution control. Herein, a hollow porous photocatalytic aerogel sphere (calcium alginate/cellulose nanofibers (CA/CNF)) loaded BiOBr/TiC, combining a favourable mass transfer structure with effective catalytic centers was firstly presented. The floatability and hollow pore structure facilitated rapid O transfer via a triphase interface, thereby promoting the generation of ROS.
View Article and Find Full Text PDFJ Biomech
January 2025
Universidade Federal de São João Del-Rei, Praça Frei Orlando, 170, São João Del Rei, Minas Gerais, Brazil. Electronic address:
The low durability of bioprosthetic heart valves (BHV), between 10-15 years, is associated with the development of leaflets flutter. Despite increasing calcification and structural damage of the BHV, leaflets flutter is an understudied condition. Therefore, the objective of this study is compare the oscillation characteristics of BHV leaflets obtained by the finite element method (FEM) technique and by the fluid-structural interaction (FSI) technique.
View Article and Find Full Text PDFMed Oral Patol Oral Cir Bucal
January 2025
Rua Monsenhor Furtado, 1273 Rodolfo Teófilo, Fortaleza CEP: 60.430-355. Ceará, Brasil
Background: The presence of mandibular third molars has been associated with the risk of mandibular fractures, highlighting the need for comprehensive studies considering the interaction with other mandibular structures. This study investigates how mandibular third molars and neighboring tissues can influence the structural fragility of the mandible using finite element analysis.
Material And Methods: A finite element analysis study following the guidelines proposed by RIFEM 1.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!