Objectives: To evaluate the diagnostic performance of MR colonography using automated carbon dioxide (CO2) insufflation for colonic distension, with colonoscopy serving as the reference standard.

Methods: Ninety-eight symptomatic patients underwent MR colonography with faecal tagging and automated CO2 insufflation. Three readers (one expert (reader 1), and two less experienced (readers 2 and 3)) evaluated the images for the presence of colorectal lesions. Bowel distension was evaluated on a 4-point scale. Results were verified with colonoscopy and histopathological analysis.

Results: Per-patient sensitivity for lesions ≥10mm was 91.7% (11 of 12) (reader 1), 75.0% (9 of 12) (reader 2), and 75% (9 of 12) (reader 3). Specificity was 96.5% (82 of 85) (reader 1), 97.7% (83 of 85) (reader 2), 95.3% (81 of 85) (reader 3). Per-patient sensitivity for lesions ≥6mm was 85.7% (18 of 21) (reader 1), 57.1% (12 of 21) (reader 2), and 57.1% (12 of 21) (reader 3). Specificity was 86.8% (66 of 76), 98.7% (75 of 76), 90.8% (69 of 76), respectively. Per-patient sensitivity for advanced neoplasia of ≥10mm and ≥6mm was 88.9% (8 of 9) for all readers. Specificity for ≥10mm and ≥6mm was 98.9% (87 of 88) (reader 1), 97.7% (86 of 88) (reader 2), 96.6% (85 of 88) (reader 3). 94.4% of the colon segments were adequate to optimal distended with dual positioning.

Conclusion: MR colonography can accurately detect lesions ≥10mm, and advanced neoplasia ≥6mm. Sufficient distension was achieved using automated CO2 insufflation for colonic distension in MR colonography.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2014.01.013DOI Listing

Publication Analysis

Top Keywords

reader
13
co2 insufflation
12
per-patient sensitivity
12
colonography automated
8
automated carbon
8
carbon dioxide
8
insufflation colonic
8
colonic distension
8
automated co2
8
sensitivity lesions
8

Similar Publications

True total-body and extended axial field-of-view (AFOV) PET/CT with 1m or more of body coverage are now commercially available and dramatically increase system sensitivity over conventional AFOV PET/CT. The Siemens Biograph Vision Quadra (Quadra), with an AFOV of 106cm, potentially allows use of significantly lower administered radiopharmaceuticals as well as reduced scan times. The aim of this study was to optimise acquisition protocols for routine clinical imaging with FDG on the Quadra the prioritisation of reduced activity given physical infrastructure constraints in our facility.

View Article and Find Full Text PDF

Objectives: To determine whether deep learning-based reconstructions of zero-echo-time (ZTE-DL) sequences enhance image quality and bone visualization in cervical spine MRI compared to traditional zero-echo-time (ZTE) techniques, and to assess the added value of ZTE-DL sequences alongside standard cervical spine MRI for comprehensive pathology evaluation.

Methods: In this retrospective study, 52 patients underwent cervical spine MRI using ZTE, ZTE-DL, and T2-weighted 3D sequences on a 1.5-Tesla scanner.

View Article and Find Full Text PDF

Background: To define optimal parameters for the evaluation of vessel visibility in intracranial stents (ICS) and flow diverters (FD) using photon-counting detector computed tomography angiography (PCD-CTA) with spectral reconstructions.

Methods: We retrospectively analyzed consecutive patients with implanted ICS or FD, who received a PCD-CTA between April 2023 and March 2024. Polyenergetic, virtual monoenergetic, pure lumen, and iodine reconstructions with different keV levels (40, 60, and 80) and reconstruction kernels (body vascular [Bv]48, Bv56, Bv64, Bv72, and Bv76) were evaluated by two radiologists with regions of interests and Likert scales.

View Article and Find Full Text PDF

During normal cellular homeostasis, unfolded and mislocalized proteins are recognized and removed, preventing the build-up of toxic byproducts. When protein homeostasis is perturbed during ageing, neurodegeneration or cellular stress, proteins can accumulate several forms of chemical damage through reactive metabolites. Such modifications have been proposed to trigger the selective removal of chemically marked proteins; however, identifying modifications that are sufficient to induce protein degradation has remained challenging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!