Interrater and intrarater reliability of common clinical standing balance tests for people with hip osteoarthritis.

Phys Ther

Y.M. Choi, DClinPhysio, Centre for Health, Exercise and Sports Medicine, Department of Physiotherapy, School of Health Sciences, The University of Melbourne, Carlton, Victoria, Australia, and Department of Rehabilitative Services, Changi General Hospital, Singapore.

Published: May 2014

Background: Hip osteoarthritis (OA) is a common musculoskeletal condition affecting older individuals. Clinical balance tests are frequently used to assess standing balance in these people. There is insufficient information regarding the reliability of these tests.

Objective: The aim of this study was to estimate reliability and measurement error of 4 common clinical standing balance tests in people with hip OA.

Design: A prospective study was conducted with repeated measures between 2 independent raters within 1 session and within 1 rater over a 1-week interval.

Methods: Thirty people with hip OA were evaluated. Reliability was estimated for the Four-Square Step Test, Step Test, Functional Reach Test, and Timed Single-Leg Stance Test using intraclass correlation coefficients (ICC [2,1]). Measurement error was expressed as standard error of measurement and minimal detectable change.

Results: The Four-Square Step Test, Step Test, and Timed Single-Leg Stance Test were sufficiently reliable between raters (ICC=.85-.94, lower 1-sided 95% confidence interval [95% CI]=.71-.89), whereas the Step Test (standing on study limb) and Timed Single-Leg Stance Test (standing on nonstudy limb) were sufficiently reliable within a rater over a 1-week interval (ICC=.91, lower 1-sided 95% CI=.80-.83). The Step Test (standing on study limb) and Timed Single-Leg Stance Test (standing on nonstudy limb) achieved optimal levels of reliability (ICC >.90, lower 1-sided 95% CI >.70), with acceptable measurement error (<10%) for clinical outcome measures. The Functional Reach Test was not sufficiently reliable. A ceiling effect was detected for the Timed Single-Leg Stance Test.

Limitations: Reliability was assessed only between 2 raters during a single session and within 1 rater over a 1-week interval, which limits generalizability.

Conclusions: The Step Test (standing on study limb) is recommended as a highly reliable test with acceptable measurement error for assessing standing balance in people with hip OA.

Download full-text PDF

Source
http://dx.doi.org/10.2522/ptj.20130266DOI Listing

Publication Analysis

Top Keywords

step test
24
timed single-leg
16
single-leg stance
16
stance test
16
test standing
16
standing balance
12
balance tests
12
people hip
12
measurement error
12
lower 1-sided
12

Similar Publications

Background: Posterior scleritis (PS) is a rare phenotype of scleritis. Comprehensive epidemiological studies on PS in children are limited. We aimed to report on its clinical and imaging features in one of the largest pediatric series to date.

View Article and Find Full Text PDF

Background: The effectiveness of rehabilitation aimed at improving the activities of daily living and physical functions may differ between hospitalized patients undergoing hemodialysis (HD) and not undergoing HD (non-HD). The aim of the present study was to compare the outcomes of rehabilitation between hospitalized HD and non-HD patients.

Methods: This was a retrospective cohort study of inpatients who underwent rehabilitation.

View Article and Find Full Text PDF

Key Performance Indicators for College American Football Starters: An Exploratory Study.

J Funct Morphol Kinesiol

January 2025

Jayhawk Athletic Performance Laboratory-Wu Tsai Human Performance Alliance, Department of Health, Sport and Exercise Sciences, University of Kansas, Lawrence, KS 66045, USA.

Objectives: The purpose of this study was twofold: (a) to profile body composition and physical fitness characteristics of collegiate American football starters and (b) to examine differences in key performance indicators across position groups. These indicators included select measures of body composition, joint kinematics, as well as muscular strength and power.

Methods: Sixteen National Collegiate Athletic Association (NCAA) Division-II American football athletes (age: 22.

View Article and Find Full Text PDF

Repeatability and Validity of Different Methods to Determine the Anaerobic Threshold Through the Maximal Multistage Test in Male Cyclists and Triathletes.

J Funct Morphol Kinesiol

December 2024

AKTIBOki, Research Group in Physical Activity, Physical Exercise and Sport, Department of Physical Education and Sport, Faculty of Education and Sport, University of the Basque Country (UPV/EHU), 01007 Vitoria-Gasteiz, Spain.

: The aim of this study was to analyze the repeatability and validity of different methods to determine the anaerobic threshold through a maximal multistage cycling test; : In total, 17 male endurance-trained athletes [7 cyclists and 10 triathletes, age 33.2 ± 6.9 yr, workload at maximal lactate steady state (MLSS) 268 ± 27 W] participated in the study.

View Article and Find Full Text PDF

: Information on the long-term maintenance of short-term exercise fitness gains measured by field-based tests is scarce in older adults. This study aimed to investigate short- and long-term changes in various physical fitness parameters after an 8-week exercise program. : In this longitudinal study, a total of 265 participants (62% women; mean age 71.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!