Single-dimension hydrogen, or proton, nuclear magnetic resonance spectroscopy (1D-(1)H NMR) has become an attractive option for characterizing the full range of components in complex mixtures of small molecular weight compounds due to its relative simplicity, speed, spectral reproducibility, and noninvasive sample preparation protocols compared to alternative methods. One challenge associated with this method is the overlap of NMR resonances leading to "convoluted" spectra. While this can be mitigated through "targeted profiling", there is still the possibility of increased quantification error. This work presents the application of a Plackett-Burman experimental design for the robust estimation of precision and accuracy of 1D-(1)H NMR compound quantification in synthetic mixtures, with application to mammalian cell culture supernatant. A single, 20 sample experiment was able to provide a sufficient estimate of bias and variability at different metabolite concentrations. Two major sources of bias were identified: incorrect interpretation of singlet resonances and the quantification of resonances from protons in close proximity to labile protons. Furthermore, decreases in measurement accuracy and precision could be observed with decreasing concentration for a small fraction of the components as a result of their particular convolution patterns. Finally, the importance of a priori concentration estimates is demonstrated through the example of interpreting acetate metabolite trends from a bioreactor cultivation of Chinese hamster ovary cells expressing a recombinant antibody.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac4033966 | DOI Listing |
Magn Reson Imaging
January 2025
Institute of Fluid Mechanics, University of Rostock, Rostock, Germany.
Purpose: To improve the current method for MRI turbulence quantification which is the intravoxel phase dispersion (IVPD) method. Turbulence is commonly characterized by the Reynolds stress tensor (RST) which describes the velocity covariance matrix. A major source for systematic errors in MRI is the sequence's sensitivity to the variance of the derivatives of velocity, such as the acceleration variance, which can lead to a substantial measurement bias.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
January 2025
Department of Analytical Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Spain. Electronic address:
The presence of cells in urine and in particular White Blood Cells (WBCs) is often associated with Urinary Tract Infections (UTIs) and other diseases. Non-invasive screening of WBCs requires the development of cost-effective point of care diagnostic tools. Infrared (IR) spectroscopy has the potential to identify and quantify cells in urine.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Inria-ASTRA Team, 48 Rue Barrault, 75013 Paris, France.
This survey extends and refines the existing definitions of integrity and protection level in localization systems (localization as a broad term, i.e., not limited to GNSS-based localization).
View Article and Find Full Text PDFJ Clin Med
January 2025
Guthrie Cortland Medical Center, Cortland, NY 13045, USA.
Artificial intelligence (AI) in echocardiography represents a transformative advancement in cardiology, addressing longstanding challenges in cardiac diagnostics. Echocardiography has traditionally been limited by operator-dependent variability and subjective interpretation, which impact diagnostic reliability. This study evaluates the role of AI, particularly machine learning (ML), in enhancing the accuracy and consistency of echocardiographic image analysis and its potential to complement clinical expertise.
View Article and Find Full Text PDFMolecules
January 2025
Institute of Mineral Resources, Chinese Academy of Geological Sciences, Beijing 100037, China.
In this paper, a method of ultrasound-assisted low-pressure closed acid digestion followed by inductively coupled plasma mass spectrometry (ICP-MS) analysis was proposed for trace element quantification in rock samples. By using 1.5 mL of a binary acid mixture of HNO-HF with a ratio of 2:1, rock powder samples of 50 mg were completely decomposed in 12 h at 140 °C after 4 h of ultrasonic treatment with or without pressure relief procedure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!