Objective: The purpose of this study is to evaluate observer detection and volume measurement of small irregular solid artificial pulmonary nodules on 64-MDCT in an anthropomorphic thoracic phantom.
Materials And Methods: Forty in-house-made solid pulmonary nodules (lobulated and spiculated; actual volume, 5.1-88.4 mm3; actual CT densities, -51 to 157 HU) were randomly placed inside an anthropomorphic thoracic phantom with pulmonary vasculature. The phantom was examined on two 64-MDCT scanners, using a scan protocol as applied in lung cancer screening. Two independent blinded observers screened for pulmonary nodules. Nodule volume was evaluated semiautomatically using dedicated software and was compared with the actual volume using an independent-samples t test. The interscanner and interobserver agreement of volumetry was assessed using Bland-Altman analysis.
Results: Observer detection sensitivity increased along with increasing size of irregular nodules. Sensitivity was 100% when the actual volume was at least 69 mm3, regardless of specific observer, scanner, nodule shape, and density. Overall, nodule volume was underestimated by (mean±SD) 18.9±11.8 mm3 (39%±21%; p<0.001). The relative interscanner difference of volumetry was 3.3% (95% CI, -33.9% to 40.4%). The relative interobserver difference was 0.6% (-33.3% to 34.5%).
Conclusion: Small irregular solid pulmonary nodules with an actual volume of at least 69 mm3 are reliably detected on 64-MDCT. However, CT-derived volume of those small nodules is largely underestimated, with considerable variation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2214/AJR.13.10830 | DOI Listing |
Clin Lung Cancer
January 2025
Thoracic Surgery Unit, IRCCS National Cancer Institute Regina Elena, Rome, Italy.
Introduction: To analyze the impact of Kirsten-Rat-Sarcoma Virus (KRAS) mutations on tumor-growth as estimated by tumor-doubling-time (TDT) among solid-dominant clinical-stage I lung adenocarcinoma. Moreover, to evaluate the prognostic role of KRAS mutations, TDT and their combination in completely-resected pathologic-stage I adenocarcinomas.
Methods: In this single-center retrospective analysis, completely resected clinical-stage I adenocarcinomas presenting as solid-dominant nodules (consolidation-to-tumor ratio > 0.
J Clin Med
January 2025
Cardiology Unit, Azienda Ospedaliero Universitaria di Ferrara, 44124 Ferrara, Italy.
The detection of unexpected findings (UF) during CT scans of patients undergoing TAVR is frequent; however, it is unclear whether such findings have a clinical impact on the TAVR pathway. We conducted a retrospective, single-center observational study enrolling patients who were candidates for TAVR. All enrolled patients underwent a CT scan before valve implantation.
View Article and Find Full Text PDFJ Clin Med
January 2025
Translational Research Unit, Hospital Universitario Miguel Servet, IIS Aragón, 50009 Zaragoza, Spain.
Lung cancer is the primary cause of cancer-related deaths. Most patients are typically diagnosed at advanced stages. Low-dose computed tomography (LDCT) has been proven to reduce lung cancer mortality, but screening programs using LDCT are associated with a high number of false positives and unnecessary thoracotomies.
View Article and Find Full Text PDFLife (Basel)
December 2024
Department of Functional Science, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.
Background And Objectives: Lung cancer screening is critical for early detection and management, particularly through the use of computed tomography (CT). This study aims to compare the Lung Imaging Reporting and Data System (Lung-RADS) Version 2022 with the British Thoracic Society (BTS) guidelines in classifying solid pulmonary nodules detected at lung cancer screening CT examinations.
Materials And Methods: This retrospective study included 224 patients who underwent lung cancer screening CT between 2016 and 2022 and had a reported solid pulmonary nodule.
Biomedicines
January 2025
Center for Research and Innovation in Precision Medicine of Respiratory Diseases, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania.
: The current study aimed to compare the effectiveness of the Lung Imaging Reporting and Data System (Lung-RADS) Version 2022 and the British Thoracic Society (BTS) guidelines in differentiating lung metastases from de novo primary lung cancer on CT scans in patients without prior cancer diagnosis. : This retrospective study included 196 patients who underwent chest CT scans between 2015 and 2022 without a known history of cancer but with detected pulmonary nodules. CT images characterized nodules based on size, number, location, margins, attenuation, and growth patterns.