Our long-term goal is the detection and characterization of vulnerable plaque in the coronary arteries of the heart using intravascular ultrasound (IVUS) catheters. Vulnerable plaque, characterized by a thin fibrous cap and a soft, lipid-rich necrotic core is a precursor to heart attack and stroke. Early detection of such plaques may potentially alter the course of treatment of the patient to prevent ischemic events. We have previously described the characterization of carotid plaques using external linear arrays operating at 9 MHz. In addition, we previously modified circular array IVUS catheters by short-circuiting several neighboring elements to produce fixed beamwidths for intravascular hyperthermia applications. In this paper, we modified Volcano Visions 8.2 French, 9 MHz catheters and Volcano Platinum 3.5 French, 20 MHz catheters by short-circuiting portions of the array for acoustic radiation force impulse imaging (ARFI) applications. The catheters had an effective transmit aperture size of 2 mm and 1.5 mm, respectively. The catheters were connected to a Verasonics scanner and driven with pushing pulses of 180 V p-p to acquire ARFI data from a soft gel phantom with a Young's modulus of 2.9 kPa. The dynamic response of the tissue-mimicking material demonstrates a typical ARFI motion of 1 to 2 microns as the gel phantom displaces away and recovers back to its normal position. The hardware modifications applied to our IVUS catheters mimic potential beamforming modifications that could be implemented on IVUS scanners. Our results demonstrate that the generation of radiation force from IVUS catheters and the development of intravascular ARFI may be feasible.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4176895PMC
http://dx.doi.org/10.1177/0161734613511595DOI Listing

Publication Analysis

Top Keywords

ivus catheters
16
radiation force
12
acoustic radiation
8
force impulse
8
impulse imaging
8
imaging arfi
8
circular array
8
vulnerable plaque
8
catheters
8
catheters short-circuiting
8

Similar Publications

Cost Analysis of Intravascular Ultrasound Guidance for Transjugular Intrahepatic Portosystemic Shunt Creation.

J Vasc Interv Radiol

January 2025

Division of Vascular & Interventional Radiology, Department of Radiology, Duke University Hospital, Durham, NC 27710. Electronic address:

Purpose: To compare costs of intravascular ultrasound (IVUS)-guided transjugular intrahepatic portosystemic shunt (TIPS) creation versus non-IVUS-guided TIPS creation, accounting for differences in procedure time and resource utilization.

Materials And Methods: This single institution retrospective study estimated procedure time and resource utilization from 157 consecutive elective TIPS creation procedures, of which 91 were IVUS-guided and 66 were non-IVUS-guided. Differences in procedure costs were derived using time-driven activity-based costing.

View Article and Find Full Text PDF
Article Synopsis
  • Heavily calcified coronary artery disease complicates percutaneous coronary intervention (PCI), requiring advanced techniques like cutting balloons (CB), which need standardization for better effectiveness.
  • The study presents the RODIN-CUT technique, which involves sequential CB inflations guided by intravascular ultrasound (IVUS) to improve plaque modification and stent expansion in difficult cases.
  • Results indicate that RODIN-CUT achieved high procedural success rates and minimal complications, suggesting it could be a simple and cost-effective method for treating calcified lesions, though larger studies are needed to confirm its validity.
View Article and Find Full Text PDF

Background: The role of Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) is still unclear in patients with STEMI undergoing PCI in the current second-generation DES era.

Aims: This study aimed to evaluate the trends and outcomes of IVUS-guided PCI in patients with STEMI.

Methods: We used the National Inpatient Sample (NIS) database from 2016 to 2021.

View Article and Find Full Text PDF

Background: Intravascular ultrasound (IVUS)-guided optimization of suboptimal fractional flow reserve (FFR) following percutaneous coronary intervention (PCI) results in a significant increase in both post-PCI FFR and minimal lumen and stent areas (MLA and MSA, respectively). However, the impact of clinical presentation with non-ST-segment elevation acute coronary syndrome (NSTE-ACS) versus chronic coronary syndrome (CCS) on the efficacy of PCI optimization remains unknown.

Methods: This was a prespecified subgroup analysis of the FFR REACT trial comparing IVUS-guided PCI optimization versus no further treatment in 291 patients with a post-PCI FFR < 0.

View Article and Find Full Text PDF

A 48-year-old male with a history of hyperlipidemia presented to the emergency department with chest pain. Electrocardiographic abnormalities indicated an acute coronary syndrome. Urgent coronary angiography revealed nondominant right coronary artery (RCA) occlusion.

View Article and Find Full Text PDF