A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the iTClamp 50 in a human cadaver model of severe compressible bleeding. | LitMetric

Evaluation of the iTClamp 50 in a human cadaver model of severe compressible bleeding.

J Trauma Acute Care Surg

From Innovative Trauma Care, Inc. (K.M., D.F., I.A.), Edmonton, Alberta; and Department of Surgery, Faculty of Medicine, University of Manitoba (S.L.), Winnipeg, Manitoba, Canada.

Published: March 2014

Background: Uncontrolled hemorrhage is a significant cause of preventable death. The iTClamp 50 is a temporary wound closure device designed to control bleeding within seconds of an injury. This study evaluates the ability of the iTClamp to control compressible bleeding in a human cadaver model.

Methods: Sterile water was pumped through the major arteries to mimic blood flow. Full-thickness, elliptical segments of skin were excised; arteriotomies or complete transections were performed on the major arteries in the thigh (distal femoral), groin (common femoral), neck (carotid), and arm (brachial). Scalp wounds were created by making a 4.4-cm linear incision to the level of the bone. Fluid losses from the wounds were compared with and without the iTClamp applied and with and without movement of the cadaver. Angiographic images of pressure-injected contrast were obtained of the neck and groin wounds. Hematoma volumes and needle penetration depth into the skin were measured.

Results: In all wounds tested, application of the iTClamp significantly reduced fluid loss in all wounds studied (p < 0.05), and movement of the cadaver did not affect the function of the iTClamp. For example, in one groin wound, the average fluid loss during 1 minute was reduced from 728.4 ± 79.3 mL to 5.6 ± 3.4 mL. Distal flow was maintained during application of the iTClamp, as illustrated in angiographic images obtained of the iTClamp applied to the neck and groin wounds. The average needle penetration depth into the skin was 4.21 ± 0.02 mm; furthermore, the iTClamp did not cause any visible skin damage or skin tearing.

Conclusion: The iTClamp is effective at controlling fluid loss from open wounds within multiple compressible areas. The iTClamp does not occlude distal flow, and aside from small needle punctures, there was no other visible skin damage or skin tearing.

Download full-text PDF

Source
http://dx.doi.org/10.1097/TA.0000000000000043DOI Listing

Publication Analysis

Top Keywords

fluid loss
12
itclamp
10
human cadaver
8
compressible bleeding
8
major arteries
8
itclamp applied
8
movement cadaver
8
angiographic images
8
neck groin
8
groin wounds
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!