A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessing a hospital's medical IT network risk management practice with 80001-1. | LitMetric

Medical device interoperability has been identified as a key way of decreasing healthcare costs while improving patient care. 1 This has led to a shift toward placing more medical devices onto information technology (IT) networks. However, placing medical devices onto an IT network may lead to additional risks to safety, effectiveness and security of the devices, the network, and the data. ANSI/AAMI/IEC 80001-1 addresses the roles, responsibilities, and activities that need to be carried out when managing these risks. In this article, we describe an exercise undertaken to assess the medical IT network risk management practice implemented within a hospital to control risk associated with a clinical information system (CIS). The level of compliance with the 80001-1 standard was determined using an assessment framework developed by the Regulated Software Research Centre. The purpose of this exercise was to test and inform the development of an assessment method that is part of the assessment framework for this standard. The exercise also sought to identify how the management of such an existing CIS project meets the requirements of 80001-1.

Download full-text PDF

Source
http://dx.doi.org/10.2345/0899-8205-48.1.64DOI Listing

Publication Analysis

Top Keywords

medical network
8
network risk
8
risk management
8
management practice
8
placing medical
8
medical devices
8
devices network
8
assessment framework
8
medical
5
assessing hospital's
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!