Background: Esophageal high-resolution manometry (HRM) allows accurate evaluation of esophageal motility. Normal values for HRM were established in the United States and several new parameters were introduced since. We aimed to provide a complete set of normal values for HRM obtained in a European population, including all current metrics used to describe the function of the upper esophageal sphincter (UES), the esophageal body, and the esophagogastric junction (EGJ).

Methods: Fifty healthy volunteers underwent esophageal HRM. Subjects swallowed 10 liquid boluses in supine position, after which UES, EGJ, and contraction wave parameters were evaluated. Mean and median values with 5-95th percentile ranges were calculated.

Key Results: The normative thresholds (5-95th percentile) for the various parameters were; UES resting pressure 34.6-137.7 mmHg, UES residual pressure 0.0-8.5 mmHg, UES 0.2-s integrated relaxation pressure (IRP) 0.0-14.5 mmHg, EGJ length 3.1-6.3 cm, EGJ resting pressure 3.0-31.2 mmHg, EGJ 4-s IRP 2.0-15.5 mmHg, intrabolus pressure (IBP) 6.6-19.5 mmHg, distal contractile integral 178-2828 mmHg*s*cm, contractile front velocity (CFV) 2.9-5.9 cm s(-1) , distal latency 5.4-8.5 s, and transition zone length 0.0-8.2 cm.

Conclusions & Inferences: Most HRM parameters assessed in this study resemble the previously described values on which the current criteria are based, supporting the widespread use of these criteria for clinical purposes. However, vigor of the esophageal contraction was lower and transition zone length larger than in previous reports. Peristaltic breaks occur frequently in healthy subjects.

Download full-text PDF

Source
http://dx.doi.org/10.1111/nmo.12314DOI Listing

Publication Analysis

Top Keywords

normal values
12
esophageal high-resolution
8
high-resolution manometry
8
european population
8
current metrics
8
values hrm
8
5-95th percentile
8
resting pressure
8
transition zone
8
zone length
8

Similar Publications

Objectives: Contrast agents are frequently administered in computed tomography (CT) scans used for opportunistic screening of osteoporosis. The objective of this study is to compare the impact of contrast-related bone mineral density (BMD) increase between phantom-based and internal CT calibration techniques.

Materials And Methods: Phantom-based and internal CT calibration techniques were used to determine trabecular BMD in 93 existing clinical CT scans of the lumbar spine of 34 subjects, scanned before and after administration of contrast agents.

View Article and Find Full Text PDF

Feasibility of on-site CT-FFR analysis on cardiac photon-counting CT in evaluation of hemodynamically significant stenosis in comparison to invasive catheter angiography.

Eur J Radiol

January 2025

Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:

Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.

View Article and Find Full Text PDF

Dogs can discriminate between people infected with SARS-CoV-2 from those uninfected, although their results vary depending on the settings in which they are exposed to infected individuals or samples of urine, sweat or saliva. This variability likely depends on the viral load of infected people, which may be closely associated with physiological changes in infected patients. Determining this viral load is challenging, and a practical approach is to use the cycle threshold (Ct) value of a RT-qPCR test.

View Article and Find Full Text PDF

Introduction: Haemodynamic atrioventricular delay (AVD) optimisation has primarily focussed on signals that are not easy to acquire from a pacing system itself, such as invasive left ventricular catheterisation or arterial blood pressure (ABP). In this study, standard clinical central venous pressure (CVP) signals are tested as a potential alternative.

Methods: Sixteen patients with a temporary pacemaker after cardiac surgery were studied.

View Article and Find Full Text PDF

Purpose: To evaluate levels of 3 tear-soluble neuropeptides in dry eye patients and to identify the correlations with clinical signs and symptoms.

Methods: A total of 16 dry eye patients and 12 healthy volunteers were enrolled. Dry eye disease (DED) diagnosis was based on the 2017 Report of the Tear Film & Ocular Surface Society International Dry Eye Workshop (TFOS DEWS II).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!