The anatomy of the larynx and trachea is well described in literature, however the intraluminal dimensions and contour of the subglottis has not been well documented. Subglottis and trachea are dynamic structures and the internal dimensions and contours have been studied only on cadavers or by plain radiograph which has many technical and measurement errors. No data is available about the internal dimensions of the subglottic and trachea in Indian population. This is the first documented study to measure the dimensions of the trachea and subglottis in Indian population. The aim of this study is to measure the internal dimensions and contour of the subglottis and upper trachea of adult Indian population. We conducted cross-sectional, observational study in a university hospital in south India to measure the dimensions of the internal subglottic and upper tracheal lumen. CT scan with 3D reconstruction with multiplanar sections was used for precise measurements. Forty-eight subjects (30 male and 18 female) who had undergone CT scan of the neck and thorax for reasons other than airway compromise were included in the study. The internal coronal diameter (CD), sagittal diameter (SD), and circumference was measured at various levels from 5 to 70 mm below the level of glottis, in the subglottis and upper trachea. Measurements of the scan for each subject were done independently by a radiologist and ENT surgeon and average of the two were documented values of each subject. These measurements were then statistically analyzed using SSPS software. The mean CD of adult Indian male ranged from 13.18 to 17.68 mm. The average intraluminal circumference ranged from 48.82 mm at the subglottis 5 mm from the glottis to a maximum of 54.96 at 30 mm. The mean CD of adult Indian female ranged from 8.7 to 15.34 mm The average intraluminal circumference ranged from 36.5 at 5 mm and a maximum of 43.05 at 70 mm. The 95% CI for the coronal, sagittal and circumference of the subglottis and upper trachea for both genders have been calculated and discussed. We have observed that the average intraluminal dimensions of the subglottis and upper trachea in south Indian population is less than that reported in western literature and earlier studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3918324PMC
http://dx.doi.org/10.1007/s12070-012-0477-xDOI Listing

Publication Analysis

Top Keywords

subglottis upper
20
upper trachea
20
indian population
20
internal dimensions
16
adult indian
16
average intraluminal
12
subglottis
9
trachea
9
study internal
8
dimensions
8

Similar Publications

Cold atmospheric plasma (CAP) devices generate reactive oxygen and nitrogen species, have antimicrobial and antiviral properties, but also affect the molecular and cellular mechanisms of eukaryotic cells. The aim of this study is to investigate CAP treatment in the upper respiratory tract (URT) to reduce the incidence of ventilator-associated bacterial pneumonia (especially superinfections with multi-resistant pathogens) or viral infections (e.g.

View Article and Find Full Text PDF

A 63-year-old Japanese woman was referred to our hospital due to dry cough, fever, hoarseness, stridor, and difficulty breathing. Chest computed tomography showed circumferential wall thickening in the trachea, carina, right main bronchus, and right upper lobe bronchus, and granular and nodular shadows in right S. Flexible laryngofiberscopy showed yellowish dry respiratory secretions adhering to the subglottis.

View Article and Find Full Text PDF

Measurement of the lengths of different sections of the upper airway and their predictive factors.

Surg Radiol Anat

July 2024

Department of Otolaryngology - Head & Neck Surgery, King Saud University Medical City, College of Medicine, King Saud University, 11411, Riyadh, Saudi Arabia.

Article Synopsis
  • * A retrospective review of 102 patients' CT scans showed that height positively correlates with the lengths of the subglottis, while older age negatively impacts the length of the extrathoracic trachea.
  • * The study found that average lengths for the anterior subglottis (14.16 mm), posterior subglottis (14.51 mm), and extrathoracic trachea (66.37 mm) vary based on factors like age, height, and sex.
View Article and Find Full Text PDF

Acquired subglottal stenosis is an unpredicted complication that can occur in some patients who have undergone prolonged endotracheal intubation. It is a narrowing of the airway at the level of the cricoid cartilage that can restrict airflow and cause breathing difficulty. Stenosis is typically treated with endoscopic airway dilation, with some patients experiencing multiple recurrences.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!