Purpose: The purpose is to compare the outcomes of FLIXENE™ arteriovenous graft (AVG) to standard polytetrafluoroethylene (PTFE) AVG for early haemodialysis.
Methods: This is a prospective observational study of all AVGs placed over a 40-month period between 2008 and 2011 at our vascular unit. Primary outcome was to examine early cannulation rates for FLIXENE™. Secondary outcomes included patency rates, usability of grafts, complications in particular infections, interventions and death in comparison to standard PTFE grafts.
Results: Forty-five FLIXENE™ and 19 standard PTFE AVGs were placed in the study period; 89% of FLIXENE™ grafts were used for dialysis, with 78% cannulated within 3 days. At 18 months, primary patency (FLIXENE™ 34% vs standard PTFE 24%), primary assisted patency (35% vs 36%) and secondary patency rate (51% vs 48%) were not statistically different; 20.2% of FLIXENE™ grafts were infected at 18 months requiring explantation compared with 40.3% of standard PTFE grafts (p=0.14).
Conclusions: FLIXENE™ can be cannulated for dialysis within 3 days. It has similar patency and complication rates as other prosthetic grafts in the market. In patients who have no access and require urgent dialysis, FLIXENE™ is a viable option.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5301/jva.5000213 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!