Safety and characterization of a novel multi-channel TMS stimulator.

Brain Stimul

Department of Life Sciences, Ben-Gurion University, Beer Sheva, Israel; Brainsway Ltd, Israel. Electronic address:

Published: May 2015

AI Article Synopsis

Article Abstract

Background: Currently available TMS stimulators have a single channel operating a single coil.

Objective: To outline and present physical and physiological benefits of a novel convenient multi-channel stimulator, comprising five channels, where the stimulation parameters of each channel are independently controllable.

Methods: Simultaneous and sequential operation of various channels was tested in healthy volunteers. Paired pulses schemes with various inter-stimulus intervals (ISIs) were studied for the hand APB and the leg AH muscles. Energy consumption and coil heating rates with simultaneous operation of 4 channels was compared to a single figure-8 coil.

Results: Repetitive operation of separate channels with different stimulation parameters is demonstrated. The operations of various channels can be combined simultaneously or sequentially to induce multiple pulses with ISIs of μs resolution. A universal pattern of inhibition and facilitation as a function of ISI was found, with some dependence on coils configurations and on pulse widths. A strong dependence of the induced inhibition on the relative orientation of the conditioning and test pulses was discovered. The ability of this method to induce inhibition in shallow brain region but not in deeper region, thus focusing the effect in the deep brain region, is demonstrated. A significant saving in energy consumption and a reduction in coil heating were demonstrated for several channels operated simultaneously compared to a standard single channel figure-8 coil.

Conclusions: The multi-channel stimulator enables the synchronized induction of different excitability modulations to different brain regions using different stimulation patterns in various channels. Multiple pulses operation with coils with various depth profiles can increase the focality of TMS effect in deep brain regions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.brs.2013.09.004DOI Listing

Publication Analysis

Top Keywords

single channel
8
multi-channel stimulator
8
channels stimulation
8
stimulation parameters
8
operation channels
8
energy consumption
8
coil heating
8
multiple pulses
8
brain region
8
deep brain
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!