Objective: To assess the performance of self-assessment gastroesophageal reflux disease questionnaire (GerdQ), 24-h impedance monitoring, proton pump inhibitor (PPI) test and intercellular space of esophageal mucosal epithelial cells in the diagnosis of gastroesophageal reflux disease (GERD).

Methods: Patients with symptoms suspected of GERD were administered the GerdQ and underwent endoscopy (measurement of intercellular space in the biopsy specimen sampling at 2 cm above the Z-line) and 24-h impedance pH monitoring, together with a 2-week experimental treatment with esomeprazole.

Results: A total of 636 patients were included for the final analysis, including 352 with GERD. The sensitivity and specificity of GerdQ and 24-h impedance monitoring for diagnosing GERD were 57.7% and 48.9%, and 66.4% and 43.3%, respectively. The sensitivity of 24-h impedance pH monitoring increased to 93.7%. The sensitivity and specificity of dilated intercellular spaces (DIS) (≥0.9 μm) for diagnosing GERD were 61.2% and 56.1%, respectively, whereas those for PPI test were 70.5% and 44.4%.

Conclusions: GerdQ score or PPI test alone cannot accurately diagnose GERD in a Chinese population suspected of GERD. A definitive diagnosis of GERD still depends on endoscopy or 24-h pH monitoring. 24-h impedance pH monitoring may increase the sensitivity for diagnosing GERD by 20%; however, when used alone, it results in poor specificity in patients without acid suppressive therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1751-2980.12135DOI Listing

Publication Analysis

Top Keywords

impedance monitoring
24
24-h impedance
20
gastroesophageal reflux
12
reflux disease
12
ppi test
12
diagnosing gerd
12
gerdq 24-h
8
intercellular space
8
gerd
8
suspected gerd
8

Similar Publications

Chronic obstructive pulmonary disease (COPD) is a leading cause of death worldwide and greatly reduces the quality of life. Utilizing remote monitoring has been shown to improve quality of life and reduce exacerbations, but remains an ongoing area of research. We introduce a novel method for estimating changes in ease of breathing for COPD patients, using obstructed breathing data collected via wearables.

View Article and Find Full Text PDF

Chemotherapy is a crucial cancer treatment, but its effectiveness requires precise monitoring of drug concentrations in patients. This study introduces an innovative electrochemical strip sensor design to detect and continuously monitor methotrexate (MTX), a key chemotherapeutic drug. The sensor is crafted through an eco-friendly synthesis process that produces porous reduced graphene oxide (PrGO), which is then integrated with gold nanocomposites and polypyrrole (PPy) to boost the performance of a screen-printed carbon electrode (SPCE).

View Article and Find Full Text PDF

The purpose of this work is to evaluate the feasibility of lung imaging using 3D electrical impedance tomography (EIT) during spontaneous breathing trials (SBTs) in patients with acute hypoxic respiratory failure. EIT is a noninvasive, nonionizing, real-time functional imaging technique, suitable for bedside monitoring in critically ill patients. EIT data were collected in 24 mechanically ventilated patients immediately preceding and during a SBT on two rows of 16 electrodes using a simultaneous multicurrent source EIT system for 3D imaging.

View Article and Find Full Text PDF

Neurodegenerative diseases, characterized by the progressive deterioration of neuronal function and structure, pose significant global public health and economic challenges. Brain-Derived Neurotrophic Factor (BDNF), a key regulator of neuroplasticity and neuronal survival, has emerged as a critical biomarker for various neurodegenerative and psychiatric disorders, including Alzheimer's disease. Traditional diagnostic methods, such as Enzyme-Linked Immunosorbent Assay (ELISA) and electrochemiluminescence (ECL) assays, face limitations in terms of sensitivity, stability, reproducibility, and cost-effectiveness.

View Article and Find Full Text PDF

Machine learning-based blood pressure estimation using impedance cardiography data.

Acta Physiol (Oxf)

February 2025

Institute of Physiology, Center for Space Medicine and Extreme Environments Berlin, Charité-Universitätsmedizin Berlin, Berlin, Germany.

Objective: Accurate blood pressure (BP) measurement is crucial for the diagnosis, risk assessment, treatment decision-making, and monitoring of cardiovascular diseases. Unfortunately, cuff-based BP measurements suffer from inaccuracies and discomfort. This study is the first to access the feasibility of machine learning-based BP estimation using impedance cardiography (ICG) data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!