A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Management of benign biliary strictures with a novel retrievable self-expandable metal stent. | LitMetric

Objective: Endoscopic placement of covered self-expandable metal stent (SEMS) has gained popularity in the management of benign biliary strictures (BBS). The existing SEMS has been designed primarily to palliate malignant biliary obstruction and has a high frequency of stent migration, difficulty in retrieval and stricture recurrence after stent removal. This study aimed to design a novel retrievable SEMS dedicated to the treatment of extrahepatic BBS and evaluate its clinical efficacy and safety.

Methods: A short fully covered SEMS (FCSEMS) with a retrieval lasso was designed for the specific treatment of BBS. A total of 45 patients with segmental extrahepatic BBS were included in this study. The stent was placed entirely inside the bile duct with only the retrieval lasso extending from the papilla. The stents were recommended to be in situ for 6 to 12 months before removal.

Results: The FCSEMS was successfully placed in all 45 patients. In all, 33 patients had their FCSEMS successfully removed after a mean period of 8.6 ± 3.7 (range 2-15.5) months. Stent migration occurred in 9.1% of the patients. During a mean follow-up of 18.9 months after stent removal, recurrent stricture was found in 2 (6.1%) patients and was successfully treated with a second FCSEMS. Overall, the strictures resolved in 30/33 (90.9%) patients.

Conclusions: Intraductal placement of a short FCSEMS is suitable for the treatment of segmental extrahepatic BBS. This new removable design offered prolonged stenting and drainage for BBS for up to one year with minimal complications.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1751-2980.12117DOI Listing

Publication Analysis

Top Keywords

extrahepatic bbs
12
management benign
8
benign biliary
8
biliary strictures
8
novel retrievable
8
self-expandable metal
8
metal stent
8
stent migration
8
stent removal
8
retrieval lasso
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!