Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The performance of immunoassays for the detection of autoantibodies is of critical importance in the diagnosis and assessment of patients with autoimmune connective tissue diseases (ACTD). Our objective was to compare the features of two multiplexed assays-INNO-LIA ANA and Gennova-PictArray ENA ELISA-for measurement of multiple autoantibodies and their utility as a clinical tool in ACTD diagnosis. The antigens included SS-A/Ro (60 and 52), SSB/La, Sm, Sm/RNP, CENP-B, Jo-1, and Scl-70. Stored sera from 85 ACTD patients and 80 controls consisting of patients with vasculitis, rheumatoid arthritis and infectious diseases, as well as healthy subjects were analyzed jointly with clinical and laboratory data. Agreement between the two methods varied between 58 and 99% (Cohen's kappa: 0.21-0.71) mostly for SSA and SSB. The frequency of specific autoantibodies measured using the two methods was more variable for SSA, SSB, and RNP/Sm. There were a higher number of ambiguous results when using INNO-LIA. The optimized cut-off values of the Gennova-PictArray resulted in over 99% specificities in samples obtained from the control group. Sensitivity patterns were more accurate in Gennova-PictArray than in INNO-LIA, as suggested in previously reported studies. A third method could be applied to determine which of the two methods is more accurate.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3914292 | PMC |
http://dx.doi.org/10.1155/2014/896787 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!