Several recent reports have described the occurrence of longitudinal stent deformation (LSD, defined as the distortion or shortening of a stent along the longitudinal axis), following its successful deployment. However, few reports have described LSD prior to any stent deployment. This previously unrecognized complication is the result of modifications to stent design. It has been noted that the new-generation stent platforms have a reduced number of connectors, which in turn causes a reduction in longitudinal stent strength. To corroborate previous findings by our lab and others (Vijayvergiya et al, 2013), we describe here two cases of LSD prior to stent deployment that occurred due to crushing of the proximal stent edge by the guide catheter while attempting to withdraw the crimped stent. In addition, we discuss the associated risk factors, such as the length of the stent, and specific management strategies, including technical guidelines and use of fluoroscopic guidance for maneuvering the stent during the procedure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3920163 | PMC |
http://dx.doi.org/10.4330/wjc.v6.i1.23 | DOI Listing |
PLoS One
January 2025
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Purpose: Treatment of peripheral artery disease (PAD) in the region below the knee (BTK) is dissatisfying as failure of treated target lesions (TLF) is frequent and diagnostic imaging is often challenging. In the BTK-region metallic drug-eluting stents (mDES) yielded best results concerning primary patency (PP), but also annihilate signal in magnetic resonance angiography (MR-A). A recently introduced non-metallic drug eluting bioresorbable Tyrocore® vascular scaffold (deBVS), that offers an option for re-treatment of lesions due to its full degradation within 3-4 years after placement, was investigated with respect to its compatibility with MR-A to unimpededly depict previously treated target lesions.
View Article and Find Full Text PDFInt J Numer Method Biomed Eng
January 2025
Hebei Provincial Key Laboratory of Portal Hypertension and Cirrhosis, Xingtai People's Hospital, Xingtai, China; Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nanjing, China.
Transjugular intrahepatic portosystemic shunt (TIPS) is a widely used surgery for portal hypertension. In clinical practice, the diameter of the stent forming a shunt is usually selected empirically, which will influence the postoperative portal pressure. Clinical studies found that inappropriate portal pressure after TIPS is responsible for poor prognosis; however, there is no scheme to predict postoperative portal pressure.
View Article and Find Full Text PDFMol Biol Rep
January 2025
Department of Biomedical Laboratory Science and Management, Vidyasagar University, Midnapore, West Bengal, 721102, India.
Background: Rising antimicrobial resistance (AMR) is an acute public health emergency impeding the clinical efficacy of surgical interventions. Biliary stent placement is one of the routine surgical procedures that rarely lead to infections that are empirically managed by broad-spectrum β-lactams and fluoroquinolones. Critical priority pathogens, such as carbapenem-resistant Escherichia coli challenge treatment outcomes and infection prevention.
View Article and Find Full Text PDFJ Robot Surg
January 2025
Pôle Santé Sud, Le Mans, France.
Pancreaticojejunostomy (PJ) is a critical step in pancreaticoduodenectomy (PD), often complicated by the risk of postoperative pancreatic fistula (POPF). This video report demonstrates a novel robotic PJ technique employing a self-expandable metallic stent. The method involves the use of the Da Vinci Xi robotic system and the WallFlex™ Biliary RX Stent for improved anastomotic support, particularly in high-risk cases defined by soft pancreatic texture and narrow duct diameter (<3 mm).
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
January 2025
Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB T6G 2R3, Canada.
Objectives: Acute type A aortic dissection (ATAAD) is a life-threatening condition that requires emergent surgical intervention. Numerous surgical approaches exist for ATAAD, and controversy remains regarding the optimal arch interventions for ATAAD patients. Aortic Arch Interventions: Approaches to ATAAD repair include hemiarch repair or extended arch repairs, including the hemiarch with a hybrid stent implantation, such as the AMDS hybrid Prosthesis, total arch replacement (TAR), and the use of an elephant trunk and frozen elephant trunk.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!