  • This study explores the use of extreme angle screws for posterior fusions in the cervical and upper thoracic spine, highlighting their advantages in rod placement without the need for adjustments.
  • Between February and July 2011, extreme angle screws were implanted in 20 adult patients with various conditions, including cervical spondylotic myelopathy and trauma, with no perioperative hardware complications reported.
  • The findings suggest that these screws enhance the strength of spinal constructs, simplify the surgical procedure, and may improve alignment, indicating a beneficial evolution in spinal instrumentation techniques.

Article Abstract

In this study, we have described our initial experience and surgical technique of extreme angle screw placement in the cervical and upper thoracic spine of a cohort of patients undergoing posterior fusion. This extreme angle screw facilitates rod placement without need for any coronal contouring of the rod or offset connectors despite the varied entry site locations for posterior instrumentation and the different trajectories and pathways of these screws. From ruary 2011 to July 2011, extreme angle screws were placed in twenty consecutive adult patients who underwent posterior cervical, occipital-cervical or cervical-thoracic fusions. The primary diagnosis was cervical spondylotic myelopathy (13), trauma (4), and pseudoarthrosis with stenosis (3). Eight patients had gross instability. A total of 196 screws were placed; half of the cases involved instrumentation at or within the C3-7 segments (10) and the others included constructs extending to occipital bone, C2, T1, or T2 (10). Of all twenty cases, there were no perioperative hardware complications. At long-term follow-up, two patients required reoperation, one for hardware failure and the other for single level symptomatic pseudoarthrosis. We conclude that extreme angle screw use in the posterior cervical spine provides an evolution in posterior instrumentation that maximizes the biomechanical strength of a construct, allows for easy rod placement, and may improve the restoration of sagittal alignment. Overall, extreme angle screws facilitate rod placement even for screws offset from the natural plane of the rod, thereby avoiding the need for coronal contouring or placement of offset connectors.

Download full-text PDF

Source

Publication Analysis

Top Keywords

extreme angle
24
angle screw
12
rod placement
12
initial experience
8
coronal contouring
8
offset connectors
8
posterior instrumentation
8
angle screws
8
posterior cervical
8
extreme
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!