Introduction And Hypothesis: Several mesh repair systems for pelvic organ prolapse (POP) were introduced into clinical practice with limited data on safety, complications or success rates, and impact on sexual function. The Austrian Urogynecology Working Group initiated a registry to assess the use of transvaginal mesh devices for POP repair. We looked at perioperative data, as well as outcomes at 3 and 12 months.
Methods: Between 2006 and 2010 a total of 20 gynecology departments in Austria participated in the Transvaginal Mesh Registry. Case report forms were completed to gather data on operations, the postoperative course, and results at 3 and 12 months.
Results: A total of 726 transvaginal procedures with 10 different transvaginal kits were registered. Intra- and perioperative complications were reported in 6.8%. The most common complication was increased intraoperative bleeding (2.2%). Bladder and bowel perforation occurred in 6 (0.8%) and 2 (0.3%) cases. Mesh exposure was seen in 11% at 3 and in 12% at 12 months. 24 (10%) previously asymptomatic patients developed bowel symptoms by 1 year. De novo bladder symptoms were reported in 39 (10%) at 3 and in 26 (11%) at 12 months. Dyspareunia was reported by 7% and 10% of 265 and 181 sexually active patients at 3 and 12 months postoperatively respectively.
Conclusions: The 6.8% rate of intra- and perioperative complications is in line with previous reports. Visceral injury was rare. The 12% rate of mesh exposure is consistent with previous series.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00192-014-2333-x | DOI Listing |
Biomed Mater
December 2024
Department of Chemical Engineering, Indian Institute of Technology - Bombay, Powai, Mumbai 400 076, Mumbai, Maharastra, 400076, INDIA.
Mechanical non-conformance of conventionally used transvaginal non-degradable meshes has led to complications like organ perforation, dyspareunia caused by mesh stiffness, and stress shielding. In this study, we have solved the dire need of mimicking the mechanical properties of vaginal wall by designing and developing a soft and elastic mesh made of polycaprolactone (PCL), citric acid modified polyethylene glycol (PEGC) and zinc oxide (ZnO) prepared through electrospinning and is tested in-vitro and in-vivo. Mesh containing 90:10:0.
View Article and Find Full Text PDFInt J Womens Health
December 2024
Department of Urology, Università "la Sapienza", ICOT, Latina, Italy.
Purpose: Surgical repair is considered the mainstay of genital prolapse management. Several procedures are available both by vaginal and abdominal route, with and without mesh augmentation. The Italian UroGynecology Association (AIUG) promoted this survey with the aim of evaluating current variations in the surgical management of various types of prolapse in different clinical settings and to compare practice amongst practitioners working in high- and medium/low-volume centers.
View Article and Find Full Text PDFJ Clin Med
December 2024
Tricomed S.A., Świętojańska 5/9, 93-493 Lodz, Poland.
The prevalence of POP in women ranges from 30-40%, with 10-20% requiring surgical intervention. Annually, over 225,000 surgical procedures for POP are performed in the United States. The severity of prolapse is assessed using the four-stage POP-Q system, which facilitates clinical research by providing a standardized measure of defect severity.
View Article and Find Full Text PDFNeurourol Urodyn
November 2024
Department of Urology, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia.
Eur J Obstet Gynecol Reprod Biol
January 2025
Women Health Center, International Medical Center (IMC) Hospital, Jeddah, Saudi Arabia.
Objective: This study evaluates the outcomes of modified transvaginal mesh (TVM) Surelift in managing advanced pelvic organ prolapse (POP) over a 3-year follow-up period, focusing on surgical success, functional improvement, and sonographic findings.
Methods: A retrospective review was conducted on 99 women who underwent Surelift System surgery for advanced POP Stage III and IV between July 2018 to January 2020. Objective evaluation included Pelvic Organ Prolapse Quantification (POP-Q), multichannel urodynamic (UDS), and introital 2D ultrasonographic measurement.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!