Background: Occlusion of the left atrial appendage (LAA) is a promising approach to stroke prevention in atrial fibrillation (AF). However, evidence of its efficacy and safety to date is lacking. We herein describe the rationale and design of a definitive LAA occlusion trial in cardiac surgical patients with AF.

Methods: We plan to randomize 4,700 patients with AF in whom on-pump cardiac surgical procedure is planned to undergo LAA occlusion or no LAA occlusion. The primary outcome is the first occurrence of stroke or systemic arterial embolism over a mean follow-up of four years. Other outcomes include total mortality, operative safety outcomes (chest tube output in the first post-operative 24 hours, rate of post-operative re-exploration for bleeding in the first 48 hours post-surgery and 30-day mortality), re-hospitalization for heart failure, major bleed, and myocardial infarction.

Results: Left Atrial Appendage Occlusion Study (LAAOS) III is funded in a vanguard phase by the Canadian Institutes for Health Research (CIHR), the Canadian Network and Centre for Trials Internationally, and the McMaster University Surgical Associates. As of September 9, 2013, 162 patients have been recruited into the study.

Conclusions: LAAOS III will be the largest trial to explore the efficacy of LAA occlusion for stroke prevention. Its results will lead to a better understanding of stroke in AF and the safety and efficacy of surgical LAA occlusion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3904329PMC
http://dx.doi.org/10.3978/j.issn.2225-319X.2013.12.06DOI Listing

Publication Analysis

Top Keywords

laa occlusion
20
left atrial
12
atrial appendage
12
laaos iii
12
rationale design
8
occlusion
8
appendage occlusion
8
occlusion study
8
study laaos
8
stroke prevention
8

Similar Publications

Preclinical Experience Using 4D Intracardiac Echocardiography to Guide Cardiac Electrophysiology Procedures.

J Cardiovasc Electrophysiol

December 2024

Division of Cardiovascular Medicine, Cardiac Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.

Introduction: Intracardiac echocardiography (ICE) is an essential imaging modality for electrophysiology procedures, allowing intraprocedural monitoring, real-time catheter manipulation guidance, and visualization of complex anatomic structures. Four-dimentional (4D) ICE is the next stage in the evolution of the technology, permitting 360° rotation of the imaging plane, simultaneous multiplanar imaging, and volumetric acquisition, similar to transesophageal echocardiography (TEE). In this study, we report our experience with a novel 4D ICE catheter (NuVision, Biosense Webster) in structural electrophysiology procedures and difficult ventricular ablations in a swine preclinical model.

View Article and Find Full Text PDF

Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.

Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.

View Article and Find Full Text PDF

Background: The congenital absence of the left atrial appendage (LAA) is an extremely rare anatomical anomaly, with only 23 cases documented in medical literature. The LAA plays a critical role in thrombus formation, particularly in patients with atrial fibrillation (AF), thus impacting stroke prevention strategies and the management of anticoagulation.

Case Summary: We report a 48-year-old male with a 2-year history of hypertension and prior episodes of tachycardic palpitations, who presented with AF and chest pain.

View Article and Find Full Text PDF

Background: Collateral circulation plays a key role in acute ischemic stroke. We sought to determine the association between the arterial collateral status, estimated by the Hypoperfusion Intensity Ratio (HIR) on perfusion MRI, and stroke etiology in anterior circulation large vessel occlusion (LVO).

Methods: We retrospectively analyzed anterior circulation LVO acute stroke patients with a baseline perfusion MRI performed within 24 h from symptom onset.

View Article and Find Full Text PDF

Objective: Hemorrhagic transformation (HT) represents a critical complication of reperfusion therapy, often resulting in unfavorable functional outcomes. Our objective was to explore the correlation between endothelial function, assessed through flow-mediated dilation (FMD), and the occurrence of HT in patients undergoing acute reperfusion therapy.

Materials And Methods: In our retrospective analysis, we investigated patients with emergent large vessel occlusion (ELVO) who underwent acute reperfusion therapy and assessment through FMD, calculated as %FMD = (peak diameter - baseline diameter)/baseline diameter×100.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!