Shrinkage of photopolymer materials is an important factor for their use in holographic data storage and for fabrication of holographic optical elements. Dimensional change in the holographic element leads to a requirement for compensation in the reading angle and/or wavelength. Normally, shrinkage is studied at the end of the polymerization process and no information about the dynamics is obtained. The aim of this study was to use holographic interferometry to measure the shrinkage that occurs during holographic recording of transmission diffraction gratings in acrylamide photopolymer layers. Shrinkage in photopolymer layers can be measured over the whole recorded area by real-time capture of holographic interferograms at regular intervals during holographic recording using a complimentary metal-oxide-semiconductor camera. The optical path length change, and hence the shrinkage, are determined from the captured fringe patterns. Through analysis of the real-time shrinkage curves, it is possible to distinguish two processes that determine the value of shrinkage in the photopolymer layer. These processes are ascribed to monomer polymerization and crosslinking of polymer chains. The dependence of shrinkage of the layers on the conditions of recording such as recording intensity, single or double beam exposure, and the physical properties of the layers, such as thickness, were studied. Higher shrinkage was observed with recordings at lower intensities and in thinner layers. Increased shrinkage was also observed in the case of single beam polymerization in comparison to the case of double beam holographic exposure.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.52.008519DOI Listing

Publication Analysis

Top Keywords

holographic recording
12
shrinkage photopolymer
12
shrinkage
11
holographic
9
holographic interferometry
8
photopolymer layers
8
double beam
8
shrinkage observed
8
recording
5
photopolymer
5

Similar Publications

This Letter discusses the limitations of immersion-free recording schemes for holographic waveguide displays. Traditional holographic recording of waveguides requires recording angles exceeding the critical angle of the hologram-cladding interface. Achieving these angles necessitates edge-lit exposure using prisms and immersion liquids, which are challenging for roll-to-roll mass production and hinder widespread adoption.

View Article and Find Full Text PDF

As the demand for computational performance in artificial intelligence (AI) continues to increase, diffractive deep neural networks (DNNs), which can perform AI computing at the speed of light by repeated optical modulation with diffractive optical elements (DOEs), are attracting attention. DOEs are varied in terms of fabrication methods and materials, and among them, volume holographic optical elements (vHOEs) have unique features such as high selectivity and multiplex recordability for wavelength and angle. However, when those are used for DNNs, they suffer from unknown wavefront aberrations compounded by multiple fabrication errors.

View Article and Find Full Text PDF

Surface relief grating formation in photo-responsive azo polymers under irradiation is a long-ago-found phenomenon, but all the factors governing its efficiency are still not fully recognized. Here, we report on the enormous impact of the polymer thickness on the possibility of fabrication of extremely high-amplitude surface deformations. We performed prolonged holographic recordings on the layers of the same azobenzene poly(ether imide), which had substantially different optical transmittances at the recording wavelength and revealed that the depths of the inscribed relief structures increased with the polymer thickness from a nondetectable value up to almost 2 µm, unaffected by the presence of a polymer-glass substrate interface in either sample.

View Article and Find Full Text PDF

An objective soft x-ray flat-field spectrograph employing a laminar-type bilayer coated, varied-line-spacing, spherical grating was designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in a region of 250-550 eV. As a design criterion, spectral flux, SF, [Hatano et al., Appl.

View Article and Find Full Text PDF

Background: 21st century neurology will require scalable and quantitative tools that can improve neurologic evaluations over telehealth and expand access to care. Commercially available mixed-reality headsets allow for simultaneous presentation of stimuli via holograms projected into the real world and objective and quantitative measurement of hand movement, eye movement, and phonation.

New Method: We created 6 tasks designed to mimic standard neurologic assessments and administered them to a single participant via the Microsoft HoloLens 2 mixed-reality headset.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!