Autonomic dysfunction assessed by EZSCAN and subclinical atherosclerosis.

J Diabetes

Key Laboratory for Endocrine and Metabolic Diseases of Ministry of Health, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, E-Institute of Shanghai Universities, Shanghai, China; Shanghai Clinical Center for Endocrine and Metabolic Diseases, Shanghai Institute of Endocrine and Metabolic Diseases, Department of Endocrine and Metabolic Diseases, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China; Laboratory of Endocrine and Metabolic Diseases, Institute of Health Sciences, Shanghai Institutes for Biological Sciences, Shanghai, China.

Published: September 2014

Background: The present study aimed to explore the association between autonomic dysfunction and measurements of atherosclerosis in a middle-aged and elderly Chinese population.

Methods: A population-based cross-sectional study was performed in Shanghai, China, from March to August 2010, with 5076 participants included in the analysis. Autonomic function was assessed by a novel EZSCAN test based on sudomotor function analysis. Carotid intima-media thickness (CIMT) was measured using B-mode ultrasonography and brachial-ankle pulse wave velocity (ba-PWV) was measured using an autonomic device. Participants were divided into three groups based on EZSCAN values: Group 1: EZSCAN 0-24; Group 2, EZSCAN 25-49; and Group 3, EZSCAN 50-100. These groups denoted autonomic dysfunction risk groups as follows: no risk, moderate risk and high risk, respectively.

Results: The prevalence of elevated CIMT and ba-PWV increased markedly with increasing EZSCAN values (elevated CIMT 7.4%, 17.5%, and 29.7%, elevated ba-PWV 3.2%, 19.7%, and 36.5%, in Groups 1, 2, and 3, respectively; both Ptrend < 0.0001). Logistic regressions revealed that EZSCAN values ≥50 were associated with a non-significantly higher risk of elevated CIMT (odds ratio [OR] = 1.43; 95% confidence interval [CI] 0.98-2.07) and a significantly higher risk of elevated ba-PWV (OR = 2.16; 95% CI 1.25-3.71) compared with EZSCAN values <25, after controlling for conventional risk factors.

Conclusion: A higher EZSCAN value (≥50), an index of high autonomic dysfunction risk, was associated with an increased risk of elevated ba-PWV and CIMT. Such associations were partially explained by traditional atherosclerotic risk factors.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1753-0407.12135DOI Listing

Publication Analysis

Top Keywords

ezscan values
16
autonomic dysfunction
12
group ezscan
12
elevated cimt
12
ezscan
9
elevated ba-pwv
8
higher risk
8
risk elevated
8
risk
6
autonomic
5

Similar Publications

Background: Chronic kidney disease (CKD) is very common now and associates with high overall and cardiovascular mortality. Numerous studies have reported that Heart rate variability (HRV) could also be used to detect cardiovascular autonomic dysfunction (CAD). We investigated the association of electrochemical skin conductance (ESC) of EZSCAN results with HRV in non-dialysis CKD patients.

View Article and Find Full Text PDF

Clinical diagnosis of diabetes mellitus (DM) is time-consuming and invasive. This study aimed to investigate the efficacy and accuracy of EZSCAN in detecting impaired glucose tolerance (IGT) and diabetes mellitus (DM) in Chinese population, and explore a diagnosis formula based on an autonomic test using EZSCAN measurement and anthropometric data. Eligible subjects (n = 1547) had the following data collected: those of anthropometric and EZSCAN measurements and biochemical tests including FPG, OGTT, HbA1c, and serum lipid tests.

View Article and Find Full Text PDF

A New Approach to Accuracy Evaluation of Single-Tooth Abutment Using Two-Dimensional Analysis in Two Intraoral Scanners.

Int J Environ Res Public Health

March 2019

Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, Seoul 03080, Korea.

The aim of this study was to two-dimensionally evaluate deviation errors at five digital cross-sections of single-tooth abutment in regards to data obtained from two intraoral scanners, and to evaluate accuracy of individual scanners. Two intraoral scanners, the Trios 3 (3 Shape, Copenhagen, Denmark) and EzScan (Vatech, Hwaseong, Korea), were evaluated by utilizing 13 stone models. The superimposed 3D data files were sectioned into five different planes: buccal-lingual section (BL), mesial-distal section (MD), transverse high section (TH), transverse middle section (TM), and transverse low section (TL).

View Article and Find Full Text PDF

Objective: Electrochemical skin conductance (ESC) is a non-invasive test of sweat function developed as a potential marker of small fiber neuropathy. Here we systematically review the evolution of this device and the data obtained from studies of ESC across different diseases.

Methods: Electronic databases, including MEDLINE, and Google Scholar were searched through to February 2018.

View Article and Find Full Text PDF

Value of EZSCAN parameters for diabetes screening in Chinese.

Med Clin (Barc)

May 2017

Department of Health Management, Third Xiangya Hospital, Central South University, Changsha, Hunan, China.

Objective: To study the parameters of EZSCAN as a screening tool for diabetes in Chinese.

Methods: A total of 6,270 subjects participated in the study. All subjects underwent tests of EZSCAN, fasting plasma glucose (FPG), oral glucose tolerance test and HbA.

View Article and Find Full Text PDF