Endoscopic scissors offer a benefit over other devices by avoiding potential complications related to thermal and mechanical injury of surrounding structures. We describe our experience with endoscopic scissors in three difficult endoscopic interventions. A fishbone embedded in the esophageal wall penetrated very close to the pulsating aorta and the bronchus. The fishbone was cut in half by endoscopic scissors and removed without injury to adjacent organs. A gastric submucosal tumor with an insulated core that could not be resected by electrosurgical devices was cut using endoscopic scissors following endoloop placement. Extravascular coil migration after transcatheter arterial embolization resulted in a duodenal ulcer. The metallic coil on the duodenal ulcer was cut by endoscopic scissors without mechanical or thermal injury.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0034-1364957DOI Listing

Publication Analysis

Top Keywords

endoscopic scissors
24
difficult endoscopic
8
endoscopic interventions
8
cut endoscopic
8
duodenal ulcer
8
endoscopic
7
scissors
6
applications endoscopic
4
scissors difficult
4
interventions endoscopic
4

Similar Publications

Background/objectives: An electric wire inserted into the bladder or urethra presents a specific challenge that is frequently encountered in such cases: the potential formation of a tight knot, making extraction nearly impossible. The primary objective of this study was to share our personal experience with patients who had intravesical electric cable insertions and to provide an extensive literature review, offering detailed insights into the various strategies reported for managing such foreign body cases.

Methods: Of the four cases with a foreign body in the lower urinary tract, two involved patients aged 19 and 53, respectively, who had inserted an electric cable.

View Article and Find Full Text PDF

A newly developed articulated through-the-scope traction device, TRACMOTION, has been used clinically for endoscopic submucosal dissection (ESD). However, there are few reports on the characteristics of this device and the lesion types for which it is most effective. Therefore, we evaluated its optimal use, efficacy, and safety clinically in animals.

View Article and Find Full Text PDF

Objective To evaluate the sterilization efficacy of hysteroscopy instruments using ultraviolet C (UV-C) light at a wavelength of 259 nm in the Endoscopic Diagnostic Center of the National Institute of Perinatology. Methods Consecutive patients undergoing office hysteroscopy via the Bettochi vaginoscopy technique were included, excluding those with conditions such as viable intrauterine pregnancy or acute pelvic infection. Samples were collected from six designated sites of the hysteroscope, including the inner sheath, internal holes of the inner sheath, lens, graspers, scissors, and outer sheath.

View Article and Find Full Text PDF

Objectives: Transoral robotic surgery (TORS) for benign glottic conditions is scarcely represented in the literature. We aimed in this study to report on the technical feasibility of an explicitly transoral robotic approach for a patient with posterior glottic stenosis, and to highlight extant limitations in exposure and robotic instrumentation of the glottis.

Methods: Retrospective chart review of a single patient undergoing a TORS approach to maximize the posterior glottic aperture.

View Article and Find Full Text PDF

Intestinal webs are either congenital or acquired. There are few reported cases of either chemotherapy or nonsteroidal anti-inflammatory medications leading to acquired intestinal webs in adults. There are limited descriptions of endoscopic interventions used for therapy of numerous duodenal webs in pediatrics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!