Background: At present there is no consensus on which technique is more suitable for the detection of right-to-left shunt (RLS) in patients with patent foramen ovale (PFO). The aim of study was to compare the efficacy of contrast transthoracic echocardiography (cTTE) and contrast transesophageal echocardiography (cTEE) in the detection of RLS.

Methods: A prospective study was undertaken in 29 patients with PFO. Both cTTE with harmonic imaging modality and cTEE with fundamental imaging modality were performed for all the patients. The severity of RLS were semiquantitatively assessed with a four-level grade system by scaling the numbers of microbubbles (MBs) in the left atrium after complete opacification of the right atrium within the first 3 cardiac cycles. Level 1 represents no MBs, indicating no RLS. Level 2, ≤10 MBs, indicating mild RLS. Level 3, 11-30 MBs, indicating moderate RLS and Level 4, >30 MBs, indicating severe RLS.

Results: Contrast TTE demonstrated significantly higher sensitivity for detection of RLS than cTEE (86% vs. 56%, P < 0.05). For cTTE, there were 4, 1, 5, and 19 cases determined at levels 1, 2, 3, and 4, respectively, whereas for the same group of patients 13, 2, 6, and 7 cases were identified by cTEE at levels 1, 2, 3, and 4, respectively. The severity of RLS detected by cTTE was significantly greater than that by cTEE (P < 0.01).

Conclusions: Contrast TTE is more efficacious in the detection of RLS than cTEE. The former can be used as an alternative to the latter in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1111/echo.12523DOI Listing

Publication Analysis

Top Keywords

mbs indicating
16
rls level
12
detection right-to-left
8
right-to-left shunt
8
patients patent
8
patent foramen
8
foramen ovale
8
contrast transthoracic
8
transthoracic echocardiography
8
contrast transesophageal
8

Similar Publications

Ultrasound localization microscopy (ULM) enables microvascular imaging at spatial resolutions beyond the acoustic diffraction limit, offering significant clinical potentials. However, ULM performance relies heavily on microbubble (MB) signal sparsity, the number of detected MBs, and signal-to-noise ratio (SNR), all of which vary in clinical scenarios involving bolus MB injections. These sources of variations underscore the need to optimize MB dosage, data acquisition timing, and imaging settings in order to standardize and optimize ULM of microvasculature.

View Article and Find Full Text PDF

: To assess the anticancer effect of microbubbles (MBs) in combination with sinoporphyrin sodium (DVDMS)-mediated sonodynamic therapy (SDT) for the in vitro and in vivo treatment of hepatocellular carcinoma (HCC). : HepG2 cells were used for in vitro experiments. Reactive oxygen species (ROS) production was detected using 2',7'-dichlorodihydrofluorescein diacetate and singlet oxygen sensor green in vitro and in solution, respectively.

View Article and Find Full Text PDF

Enhanced Protein Immobilization Capacity through Grafting of Poly(sodium methacrylate) onto Magnetic Bead Surface.

Langmuir

January 2025

School of Chemistry and Chemical Engineering, Jiangsu Province Hi-Tech Key Laboratory for Biomedical Research, Southeast University, Nanjing, Jiangsu 211189, P. R. China.

Article Synopsis
  • The study focuses on enhancing the signal-to-noise ratio (SNR) in chemiluminescence immunoassays (CLIA) by increasing the amount of protein attached to magnetic beads (MBs).
  • To achieve this, researchers grafted a functional polymer, poly(sodium methacrylate) (P-COONa), onto the MBs to improve both the density and three-dimensional distribution of functional groups.
  • Experimental results showed that the grafting process significantly boosted protein immobilization and improved the SNR, with substantial increases in BSA attachment and biomarker detection capabilities.
View Article and Find Full Text PDF

Purpose: An accurate assessment of time spent in 24-hour movement behaviors (24 h-MBs) is crucial in exploring health related associations. This study aims to evaluate the concurrent validity of the Daily Activity Behavior Questionnaire (DABQ) compared to the ActiGraph using absolute and relative indicators of validity.

Methods: This cross-sectional observational study included 105 adults (45 ± 13 y/o, 54% female).

View Article and Find Full Text PDF

CRISPR/Cas12a-Enabled Amplification-Free Colorimetric Visual Sensing Strategy for Point-of-Care Diagnostics of Biomarkers.

Anal Chem

December 2024

Cancer Research Center & Jiangxi Engineering Research Center for Translational Cancer Technology, Jiangxi University of Chinese Medicine & Jiangxi Province Key Laboratory for Diagnosis, Treatment and Rehabilitation of Cancer in Chinese Medicine, Nanchang, Jiangxi 330004, China.

CRISPR/Cas12a-based biosensors have garnered significant attention in the field of point-of-care testing (POCT), yet the majority of the CRISPR-based POCT methods employ fluorescent systems as report probes. Herein, we report a new CRISPR/Cas12a-enabled multicolor visual biosensing strategy for the rapid detection of disease biomarkers. The proposed assay provided vivid color responses to enhance the accuracy of visual detection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!