A mesoporous silica film (MSF) with vertically oriented mesochannels on a conductive substrate serves as a hard-template for electrodeposition of polyaniline (PANI). The PANI nanostructures thus prepared are orderly confined in silica mesochannels, eventually producing a robust hybrid film. The film displays a good electrocatalytic activity toward oxidation of ascorbic acid, and can be used for potentiometric pH sensing with a Nernstian response.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/chem.201303807 | DOI Listing |
This paper explores the process of forming arrays of vertically oriented carbon nanotubes (CNTs) localized on metal electrodes using thin porous anodic alumina (PAA) on a solid substrate. On a silicon substrate, a titanium film served as the electrode layer, and an aluminium film served as the base layer in the initial film structure. A PAA template was formed from the Al film using two-step electrochemical anodizing.
View Article and Find Full Text PDFNat Commun
January 2025
Department of Civil and Environmental Engineering, Rice University, Houston, TX, USA.
Gypsum (CaSO·2HO) plays a critical role in numerous natural and industrial processes. Nevertheless, the underlying mechanisms governing the formation of gypsum crystals on surfaces with diverse chemical properties remain poorly understood due to a lack of sufficient temporal-spatial resolution. Herein, we use in situ microscopy to investigate the real-time gypsum nucleation on self-assembled monolayers (SAMs) terminated with -CH, -hybrid (a combination of NH and COOH), -COOH, -SO, -NH, and -OH functional groups.
View Article and Find Full Text PDFJ Radiol Prot
January 2025
Radiation Protection Dosimetry (6.3), Physikalisch-Technische Bundesanstalt, Braunschweig, NDS, GERMANY.
With the International Commission on Radiological Protection (ICRP) lowering the annual dose limit for the eye lens to 20 mSv, precise monitoring of eye lens exposure has become essential. The personal dose equivalent at a depth of 3 mm, Hp(3), is the measurement method for monitoring the dose to the lens of the eye. Traditional dosimetry methods primarily address lateral radiation exposure scenarios, where radiation approaches from the left or right, necessitating the rotation of the phantom during type testing around the vertical axis.
View Article and Find Full Text PDFAnn Phys Rehabil Med
January 2025
University Grenoble Alpes, UMR CNRS 5105 Neuropsychology and NeuroCognition, CHU Grenoble Alpes, Dept of NeuroRehabilitation South Hospital, Cs 10217-38043 Grenoble cedex 9, France. Electronic address:
Background: Many signs of spatial dysgraphia and drawing errors after right hemispheric stroke (RHS) have been attributed to spatial neglect or impaired sensory feedback. Counterclockwise (contralesional) tilts of graphomotor productions remained to be explained.
Objective: To test whether graphomotor tilts stem from a tilted representation of verticality transposed to the top/bottom axis of the sheet of paper, using data from the DOBRAS cohort.
J Prosthodont Res
January 2025
Department of Prosthodontics, Faculty of Dentistry, Ibb University, Ibb, Yemen.
Purpose: This systematic review evaluated the effect of different printing orientations on the physical-mechanical properties and accuracy of resin denture bases and related specimens.
Study Selection: Utilizing PRISMA 2020 guidelines, a comprehensive search of PubMed, Web of Science, Cochrane, and Scopus databases was conducted until June 2024. Included studies examined the accuracy, volumetric changes, and mechanical or physical properties of 3D-printed denture bases in various orientations.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!