Purpose: Multispectral imaging (MSI) significantly reduces metal artifacts. Yet, especially in techniques that use gradient selection, such as slice encoding for metal artifact correction (SEMAC), a residual ripple artifact may be prominent. Here, an analysis is presented of the ripple artifact and of slice overlap as an approach to reduce the artifact.

Methods: The ripple artifact was analyzed theoretically to clarify its cause. Slice overlap, conceptually similar to spectral bin overlap in multi-acquisition with variable resonances image combination (MAVRIC), was achieved by reducing the selection gradient and, thus, increasing the slice profile width. Time domain simulations and phantom experiments were performed to validate the analyses and proposed solution.

Results: Discontinuities between slices are aggravated by signal displacement in the frequency encoding direction in areas with deviating B0. Specifically, it was demonstrated that ripple artifacts appear only where B0 varies both in-plane and through-plane. Simulations and phantom studies of metal implants confirmed the efficacy of slice overlap to reduce the artifact.

Conclusion: The ripple artifact is an important limitation of gradient selection based MSI techniques, and can be understood using the presented simulations. At a scan-time penalty, slice overlap effectively addressed the artifact, thereby improving image quality near metal implants.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.25127DOI Listing

Publication Analysis

Top Keywords

ripple artifact
20
slice overlap
20
slice
8
slice encoding
8
encoding metal
8
metal artifact
8
artifact correction
8
gradient selection
8
simulations phantom
8
metal implants
8

Similar Publications

Connectivity of high-frequency bursts as SOZ localization biomarker.

Front Netw Physiol

September 2024

Biomedical Engineering Department, University of California, Irvine, Irvine, CA, United States.

Article Synopsis
  • The study focuses on improving the identification of seizure onset zones (SOZ) in patients with refractory epilepsy using a new metric called channel-level connectivity dispersion (CLCD) to analyze brain activity.
  • CLCD measures the variability in synchronization between individual electrodes and aims to identify connections associated with abnormal brain activity linked to SOZ.
  • The method was tested on two datasets of intracranial electroencephalography signals, showing promising results in differentiating SOZ channels from non-SOZ channels based on lower CLCD values.
View Article and Find Full Text PDF

Purpose: High resolution fMRI is a rapidly growing research field focused on capturing functional signal changes across cortical layers. However, the data acquisition is limited by low spatial frequency EPI artifacts; termed here as Fuzzy Ripples. These artifacts limit the practical applicability of acquisition protocols with higher spatial resolution, faster acquisition speed, and they challenge imaging in lower brain areas.

View Article and Find Full Text PDF

Purpose: Chest tomosynthesis (CTS) has a relatively longer acquisition time compared with chest X-ray, which may increase the risk of motion artifacts in the reconstructed images. Motion artifacts induced by breathing motion adversely impact the image quality. This study aims to reduce these artifacts by excluding projection images identified with breathing motion prior to the reconstruction of section images and to assess if motion compensation improves overall image quality.

View Article and Find Full Text PDF

The current study proposed and evaluated "residual squeeze and excitation attention gate" (rSEAG), a novel network that can improve image quality by reducing distortion attributed to artifacts. This method was established by modifying the Cycle Generative Adversarial Network (cycleGAN)-based generator network using projection data for pre-reconstruction processing in digital breast tomosynthesis. Residual squeeze and excitation were installed in the bridge of the generator network, and the attention gate was installed in the skip connection between the encoder and decoder.

View Article and Find Full Text PDF

Description Too much to counsel on, too little time? We would like to present a unique and innovative perspective on lifestyle medicine counseling through the lens of a homemade flyer, designed to bridge the gap between conventional health care practices and personalized, holistic well-being. In the promising field of health care humanities, the homemade lifestyle medicine flyer serves as a tangible manifestation of individual agency in promoting health and vitality. The flyer encapsulates a diverse range of self-care practices, dietary insights, and mindfulness techniques, emphasizing the inherent connection between mind, body, and spirit in one's health journey.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!