Molecular dynamics simulations with varying damping are used to examine the effects of inertia and spatial dimension on sheared disordered solids in the athermal quasistatic limit. In all cases the distribution of avalanche sizes follows a power law over at least three orders of magnitude in dissipated energy or stress drop. Scaling exponents are determined using finite-size scaling for systems with 10(3)-10(6) particles. Three distinct universality classes are identified corresponding to overdamped and underdamped limits, as well as a crossover damping that separates the two regimes. For each universality class, the exponent describing the avalanche distributions is the same in two and three dimensions. The spatial extent of plastic deformation is proportional to the energy dissipated in an avalanche. Both rise much more rapidly with system size in the underdamped limit where inertia is important. Inertia also lowers the mean energy of configurations sampled by the system and leads to an excess of large events like that seen in earthquake distributions for individual faults. The distribution of stress values during shear narrows to zero with increasing system size and may provide useful information about the size of elemental events in experimental systems. For overdamped and crossover systems the stress variation scales inversely with the square root of the system size. For underdamped systems the variation is determined by the size of the largest events.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/PhysRevE.88.062206 | DOI Listing |
J Racial Ethn Health Disparities
January 2025
Valleywise Health, Phoenix, AZ, USA.
Background: Missed clinic appointments disproportionately affect Medicaid-insured patients and residents of socioeconomically deprived neighborhoods. The role of the recent telemedicine expansion in reducing these disparities is unclear. We analyzed the relationship between census tract (CT) poverty level, residential segregation, missed appointments, and the role of telemedicine.
View Article and Find Full Text PDFJpn J Radiol
January 2025
Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Purpose: To evaluate the effects of four-dimensional noise reduction filtering using a similarity algorithm (4D-SF) on the image quality and tumor visibility of low-dose dynamic computed tomography (CT) in evaluating breast cancer.
Materials And Methods: Thirty-four patients with 38 lesions who underwent low-dose dynamic breast CT and were pathologically diagnosed with breast cancer were enrolled. Dynamic CT images were reconstructed using iterative reconstruction alone or in combination with 4D-SF.
AAPS PharmSciTech
January 2025
College of Pharmacy, Jiangxi University of Chinese Medicine, Nanchang, 330004, China.
Valsartan (VST) is an angiotensin II receptor antagonist with low oral bioavailability. The present study developed a solid self-nanoemulsifying drug delivery system (S-SNEDDS) to enhance the oral absorption and bioavailability of VST. VST-loaded liquid SNEDDS (VST@L-SNEDDS) was prepared by investigating the solubility of VST and constructing the pseudo-ternary phase diagrams.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Life Sciences, Imperial College, London, SW7 2AZ, UK.
Many cellular patterns exhibit a reaction-diffusion component, suggesting that Turing instability may contribute to pattern formation. However, biological gene-regulatory pathways are more complex than simple Turing activator-inhibitor models and generally do not require fine-tuning of parameters as dictated by the Turing conditions. To address these issues, we employ random matrix theory to analyze the Jacobian matrices of larger networks with robust statistical properties.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Oral and Maxillofacial Surgery, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany.
This experimental phantom study investigates current standard of care protocols in cone beam computed tomography (CBCT), energy-integrating-detector (EID) CT, and photon-counting-detector (PCD) CT regarding their potential in delineation of dental root canals. Artificial accessory canals (diameters: 1000, 600, 400, 300 and 200 μm) were drilled into three bovine teeth mounted on a bovine rib as a jaw substitute. The phantom was scanned in two dental CBCTs, two EID-CTs and a PCD-CT using standard clinical protocols.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!