A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and Validation of a Stability-Indicating RP-HPLC Method for the Simultaneous Determination of Phenoxyethanol, Methylparaben, Propylparaben, Mometasone Furoate, and Tazarotene in Topical Pharmaceutical Dosage Formulation. | LitMetric

A stability-indicating RP-HPLC method has been developed and validated for the simultaneous determination of phenoxyethanol (PE), methylparaben (MP), propylparaben (PP), mometasone furoate (MF), and tazarotene (TA) in topical pharmaceutical dosage formulation. The desired chromatographic separation was achieved on the Waters X-Bridge™ C18 (50×4.6mm, 3.5μ) column using gradient elution at 256 nm detection wavelength. The optimized mobile phase consisted of 0.1%v/v orthophosphoric acid in water as solvent-A and acetonitrile as solvent-B. The method showed linearity over the range of 5.88-61.76 μg/mL, 0.18-62.36 μg/mL, 0.17-6.26 μg/mL, 0.47-31.22 μg/mL, and 0.44-30.45 μg/mL for PE, MP, PP, MF, and TA, respectively. The recovery for all of the components was in the range of 98-102%. The stability-indicating capability of the developed method was established by analysing the forced degradation samples, in which the spectral purity of PE, MP, PP, MF, and TA along with the separation of degradation products from the analyte peaks was achieved. The proposed method was successfully applied for the quantitative determination of PE, MP, PP, MF, and TA in a cream sample.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3867250PMC
http://dx.doi.org/10.3797/scipharm.1303-22DOI Listing

Publication Analysis

Top Keywords

stability-indicating rp-hplc
8
rp-hplc method
8
simultaneous determination
8
determination phenoxyethanol
8
phenoxyethanol methylparaben
8
methylparaben propylparaben
8
propylparaben mometasone
8
mometasone furoate
8
furoate tazarotene
8
tazarotene topical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!