AI Article Synopsis

  • Pneumonia is a widespread illness that can be hard to diagnose, prompting studies into using lung ultrasound as a diagnostic tool, with mixed results prior to this research.
  • This study conducted a meta-analysis of nine studies involving 1080 subjects to evaluate the diagnostic accuracy of lung ultrasound for pneumonia, finding it has high sensitivity (97%) and specificity (94%).
  • The findings suggest that lung ultrasound is a highly accurate method for diagnosing pneumonia, providing a potentially better alternative to traditional imaging methods like chest X-rays and CT scans.

Article Abstract

Background And Objective: Pneumonia is a common disease with both high morbidity and mortality, the diagnosis of pneumonia remains a clinical challenge. Many studies have been conducted to identify the usefulness of lung ultrasound for the diagnosis of pneumonia, but with inconsistent and inconclusive results. The present study aimed to establish the overall diagnostic accuracy of lung ultrasound in diagnosing pneumonia.

Methods: Based on a comprehensive search of the Pubmed, Embase, and the Cochrane database, we identified out-come data from all articles estimating diagnostic accuracy with lung ultrasound for pneumonia. Quality was assessed with the Quality Assessment for Diagnostic Accuracy Studies. Results from different studies were pooled using a bivariate meta-analysis. Summary receiver operating characteristic curve was used to assess the overall performance of lung ultrasound-based assays.

Results: Nine studies containing 1080 subjects were included in this meta-analysis. The summary estimates for lung ultrasound in the diagnosis of pneumonia in the studies included were as follows: sensitivity, 0.97 (95% CI: 0.93-0.99); specificity, 0.94 (95% CI: 0.85-0.98); DOR, 507.99 (95% CI: 128.11-2014.34); positive likelihood ratio, 15.62 (95% CI: 6.31-38.68); negative likelihood ratio, 0.03 (95% CI: 0.01-0.08); The area under the summary receiver operating characteristic curve was 0.99 (95% CI: 0.98-1.00).

Conclusion: Lung ultrasound is a capable of diagnosing pneumonia with high accuracy and is a promising attractive alternative to chest radiography and thoracic CT scan.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3902248PMC

Publication Analysis

Top Keywords

lung ultrasound
24
diagnosis pneumonia
16
ultrasound diagnosis
12
diagnostic accuracy
12
performance lung
8
bivariate meta-analysis
8
accuracy lung
8
meta-analysis summary
8
summary receiver
8
receiver operating
8

Similar Publications

Enhancing Diagnostic Accuracy of Lung Nodules in Chest Computed Tomography Using Artificial Intelligence: Retrospective Analysis.

J Med Internet Res

January 2025

Department of Health Policy and Management, Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD, United States.

Background: Uncertainty in the diagnosis of lung nodules is a challenge for both patients and physicians. Artificial intelligence (AI) systems are increasingly being integrated into medical imaging to assist diagnostic procedures. However, the accuracy of AI systems in identifying and measuring lung nodules on chest computed tomography (CT) scans remains unclear, which requires further evaluation.

View Article and Find Full Text PDF

In 2019, the novel coronavirus swept the world, exposing the monitoring and early warning problems of the medical system. Computer-aided diagnosis models based on deep learning have good universality and can well alleviate these problems. However, traditional image processing methods may lead to high false positive rates, which is unacceptable in disease monitoring and early warning.

View Article and Find Full Text PDF

The widespread adoption of high-resolution computed tomography (CT) screening has led to increased detection of small pulmonary nodules, necessitating accurate localization techniques for surgical resection. This review examines the evolution, efficacy, and safety of various localization methods for small pulmonary nodules. Studies focusing on localization techniques for pulmonary nodules ≤30 mm in diameter were included, with emphasis on technical success rates and complication profiles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!