This paper describes a theory of the kinetic analysis of patch-clamp data. We assume that channel gating is a Markov process that can be described by a model consisting of n kinetic states and n(n - 1) rate constants at each voltage, and that patch-clamp data describe the occupancy of x different conductance levels over time. In general, all the kinetic information in a set of patch-clamp data is found in either two-dimensional dwell time histograms describing the frequency of observation of sequential dwell times of durations tau 1 and tau 2 (Fredkin, D. R., M. Montal, and J. A. Rice, 1985, Proceedings of the Berkeley Conference in Honor of Jerzy Neyman and Jack Kiefer, vol. 1, 269-289) or in three-point joint probability functions describing the probability that a channel is in a given conductance at time t, and at time t + tau 1, and at time t + tau 1 + tau 2. For the special case of channels with a single open state plus multiple closed states, one-dimensional analyses provide all of the kinetic information. Stationary patch-clamp data have information that can be used to determine H rate constants, where H = n(n - 1) - G and G is the number of intraconductance rate constants. Thus, to calculate H rate constants, G rate constants must be fixed. In general there are multiple sets of G rate constants that can be fixed to allow the calculation of H rate constants although not every set of G rate constants will work. Arbitrary assignment of the G intraconductance rate constants equal to zero always provides a solution and the calculation of H rate constants. Nonstationary patch-clamp data have information for the determination of H rate constants at a reference voltage plus n(n - 1) rate constants at all test voltages. Thus, nonstationary data have extra information about the voltage dependencies of rate constants that can be used to rule out kinetic models that cannot be disqualified on the basis of stationary data.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1330095 | PMC |
http://dx.doi.org/10.1016/S0006-3495(87)83289-7 | DOI Listing |
J Vet Emerg Crit Care (San Antonio)
January 2025
J. T. Vaughan Large Animal Teaching Hospital, Auburn University, Auburn, Alabama, USA.
Objective: To investigate the volume kinetic between 2 crystalloid fluid bolus rates in anesthetized cats.
Design: Prospective, randomized, dose-response study.
Setting: University laboratory.
Med Devices (Auckl)
January 2025
Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
Purpose: The aim of this study was to use calorimetry to understand the difference in energy transferred by three phacoemulsification surgical platforms to the eye.
Patients And Methods: A phacoemulsification tip was lowered into a double-walled calorimeter filled with distilled water. The foot pedal was depressed for 30 seconds and the change in temperature of the water was measured by a temperature probe.
Front Cell Infect Microbiol
January 2025
The First Affiliated Hospital of Gannan Medical University, Ganzhou, Jiangxi, China.
Objective: To establish a rapid detection method for canine using recombinase-aided amplification (RAA) technology.
Methods: The outer membrane protein 25 gene fragment (Omp25) of canis was targeted. Primers and fluorescent probes were designed and synthesized, and recombinant plasmids were constructed as standards.
RSC Adv
January 2025
Institute of Sciences and Technology, TNU-University of Sciences Thai Nguyen 250000 Vietnam
The sonochemical synthesis of a chitosan-ZnO/FeO nanocomposite yielded a highly porous structure and large surface area for enhancing the photocatalytic degradation of cationic (rhodamine B, RhB) and anionic (methyl orange, MO) dyes in aqueous solution. Chitosan-ZnO/FeO demonstrated a significant enhancement in photodegradation efficiency 99.49% for MO ( = 5.
View Article and Find Full Text PDFShoulder Elbow
January 2025
Department of Orthopaedic Surgery, Capio St Görans Hospital, Stockholm, Sweden.
Background: The aim of this study was to evaluate clinical results and complication rate in patients with proximal humeral fracture treated with Anatomical Locking Plate System (A.L.P.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!