Influence of surgical drills wear on thermal process generated in bones.

Acta Bioeng Biomech

Department of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Zabrze, Poland.

Published: September 2014

The influence of the wear rate of drills used in bone surgery on the temperature distribution in the femur models (Sawbones) is presented in the paper. Surgical drills of diameter d = 4.5 mm and diverse edge geometry (90° and 120°) were selected for the study. In order to carry out thermal analysis with the use of finite element, experimental studies of wear process were necessary. These studies, among others, consisted in determination of average values of axial forces and cutting torques as a function of the number of drilled holes. The study showed an impact of the drill geometry on values that describe cutting process. It was found that the greatest values of torques and axial cutting forces occur in drills of point angle of 120°. Next, in order to determine the effect of wear rate on the generation of temperature in the cutting zone, thermal analysis of the drilling process using the finite element method was carried out. It was found that higher temperatures in the bone are observed for drilling with the use of the drill of point angle equal to 120°, as in the experimental study. For the tools of such edge geometry the wear of cutting edge is more intensive and the generated temperature in femur for the wear land VBB = 0.32 mm has reached the critical value associated with the process of thermal necrosis.

Download full-text PDF

Source

Publication Analysis

Top Keywords

surgical drills
8
wear rate
8
edge geometry
8
thermal analysis
8
finite element
8
point angle
8
wear
6
process
5
cutting
5
influence surgical
4

Similar Publications

Purpose: Cochlear implants (CI) are the most successful bioprosthesis in medicine probably due to the tonotopic anatomy of the auditory pathway and of course the brain plasticity. Correct placement of the CI arrays, respecting the inner ear anatomy are therefore important. The ideal trajectory to insert a cochlear implant array is defined by an entrance through the round window membrane and continues as long as possible parallel to the basal turn of the cochlea.

View Article and Find Full Text PDF

Smartphone application-based augmented reality for pre-clinical dental implant placement training: a pilot study.

Oral Maxillofac Surg

January 2025

Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Steiner Landstraße 123, Krems an der Donau, 3500, Austria.

Purpose: Precise implant placement is essential for optimal functional and aesthetic outcomes. Digital technologies, such as computer-assisted implant surgery (CAIS), have improved implant outcomes. However, conventional methods such as static and dynamic CAIS (dCAIS) require complex equipment.

View Article and Find Full Text PDF

The endoscopic transsphenoidal approach is a common approach used in skull base neurosurgery to reach the sellar region. One of the intraoperative risks of this approach is intraoperative bleeding out of the carotid artery. Gentle drilling can prevent carotid artery injury.

View Article and Find Full Text PDF

Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.

View Article and Find Full Text PDF

The emergence of augmented reality (AR) in surgical procedures could significantly enhance accuracy and outcomes, particularly in the complex field of orthognathic surgery. This study compares the effectiveness and accuracy of traditional drilling guides with two AR-based navigation techniques: one utilizing ArUco markers and the other employing small-workspace infrared tracking cameras for a drilling task. Additionally, an alternative AR visualization paradigm for surgical navigation is proposed that eliminates the potential inaccuracies of image detection using headset cameras.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!