Volumetric quantification of type II endoleaks: an indicator for aneurysm sac growth following endovascular abdominal aortic aneurysm repair.

Radiology

From the Department of Radiology (J.S., K.K.K., N.W., E.G., M.L.S., F.J.R.), Applied Imaging Science Laboratory (S.D., J.S., K.K.K., N.W., E.G., M.L.S., F.J.R.), and Department of Vascular Surgery (E.C.G.), Brigham and Women's Hospital, Boston, Mass.

Published: April 2014

Purpose: To test the hypothesis that type II endoleak cavity volume (ECV) and endoleak cavity diameter (ECD) measurements are accurate indicators of aneurysm sac volume (ASV) enlargement in patients who undergo endovascular aneurysm repair (EVAR) in the abdominal aorta.

Materials And Methods: The institutional review board approved and waived the need to obtain patient consent for this HIPAA-compliant retrospective study. In 72 patients who underwent EVAR, 160 computed tomographic (CT) angiography studies revealed type II endoleaks. Corresponding to these 160 CT angiography studies, 113 CT follow-up studies (in 52 patients) were available and were included in the analysis. ECV measurements were obtained by two observers in consensus by using arterial enhanced phase (ECVAEP) and 70-second delayed enhanced phase (ECVDEP) CT images. The ECVDEP was also normalized as the ECV/ASV ratio. Maximum (ECDM) and transverse (ECDT) ECDs were determined from delayed enhanced phase images. The outcome was determined as interval increase (>2%) in ASV versus stable or decreasing (≤2%) ASV. Receiver operating characteristic (ROC) analysis was used to compare the accuracy of type II ECV and ECD measurements in indicating interval increase in ASV.

Results: In 56 (49.5%) of 113 CT studies in type II endoleaks, there was an interval increase in ASV. The accuracies of ECVDEP (area under the ROC curve [AUC], 0.85) and normalized ECVDEP (AUC, 0.86) were superior to the accuracies of ECDM (AUC, 0.73), ECDT (AUC, 0.73), and ECVAEP (AUC, 0.66). At ROC curve analysis, the sensitivity, specificity, and positive and negative predictive values for type II endoleak cavities with an ECVDEP of less than 0.5 mL for showing no future sac volume enlargement were 33% (19 of 57), 100% (56 of 56), 100% (19 of 19), and 60% (56 of 94), respectively.

Conclusion: With use of the delayed enhanced phase of CT angiography, ECV measurement is an accurate indicator of aneurysm sac enlargement.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.13130157DOI Listing

Publication Analysis

Top Keywords

enhanced phase
16
type endoleaks
12
aneurysm sac
12
delayed enhanced
12
interval increase
12
indicator aneurysm
8
aneurysm repair
8
type endoleak
8
endoleak cavity
8
ecd measurements
8

Similar Publications

Background: This study aimed to create a comprehensive Core Outcome Set (COS) for assessing the long-term outcome (≥ 5 years) after Metabolic Bariatric Surgery (MBS), through the use of the Delphi method.

Methods: The study utilized a three-phase approach. In Phase 1, a long list of items was identified through a literature review and expert input, forming the basis for an online Delphi survey.

View Article and Find Full Text PDF

New Numerical Inversion Method to Improve the Spatial Accuracy of Elemental Imaging for LA-ICP-MS.

Anal Chem

January 2025

State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan 430074, PR China.

The elemental imaging of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) provides spatial information on elements and therefore can further investigate the growth or evolution processes of an analyte. However, the accurate determination of spatial information is limited by the decoupling between the elemental distribution and mass spectrometry signals. This phenomenon, which is more distinct when high-diffusion ablation cells are used, arises from the overlap of ablation and the transport dispersion of aerosols.

View Article and Find Full Text PDF

Serving as a dedicated process analytical technology (PAT) tool for biomass monitoring and control, the capacitance probe, or dielectric spectroscopy, is showing great potential in robust pharmaceutical manufacturing, especially with the growing interest in integrated continuous bioprocessing. Despite its potential, challenges still exist in terms of its accuracy and applicability, particularly when it is used to monitor cells during stationary and decline phases. In this study, data pre-processing methods were first evaluated through cross-validation, where the first-order derivative emerged as the most effective method to diminish variability in prediction accuracy across different training datasets.

View Article and Find Full Text PDF

Purpose: The aim of the work is to develop a cascaded diffusion-based super-resolution model for low-resolution (LR) MR tagging acquisitions, which is integrated with parallel imaging to achieve highly accelerated MR tagging while enhancing the tag grid quality of low-resolution images.

Methods: We introduced TagGen, a diffusion-based conditional generative model that uses low-resolution MR tagging images as guidance to generate corresponding high-resolution tagging images. The model was developed on 50 patients with long-axis-view, high-resolution tagging acquisitions.

View Article and Find Full Text PDF

Purpose: Pulmonary MRI faces challenges due to low proton density, rapid transverse magnetization decay, and cardiac and respiratory motion. The fermat-looped orthogonally encoded trajectories (FLORET) sequence addresses these issues with high sampling efficiency, strong signal, and motion robustness, but has not yet been applied to phase-resolved functional lung (PREFUL) MRI-a contrast-free method for assessing pulmonary ventilation during free breathing. This study aims to develop a reconstruction pipeline for FLORET UTE, enhancing spatial resolution for three-dimensional (3D) PREFUL ventilation analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!