Background: Immunoassays for Plasmodium detection are, presently, most frequently based on monoclonal antibodies (MAbs); Polyclonal antibodies (PAbs), which are cheaper to develop and manufacture, are much less frequently used. In the present study we describe a sandwich ELISA assay which is capable of detecting P. vivax Lactate Dehydrogenase (LDH) in clinical blood samples, without cross reacting with those infected with P. falciparum.
Methods: Two recombinant proteins were produced from different regions of the P. vivax LDH gene. Two sandwich ELISA assay were then designed: One which uses mouse anti-LDH 1-43aa PAbs as primary antibodies ("Test 1") and another which uses anti-LDH 35-305aa PAbs ("Test 2") as the primary antibodies. Rabbit anti-LDH 1-43aa PAbs were used as capture antibodies in both ELISA assays. Blood samples taken from P. vivax and P. falciparum infected patients (confirmed by light microscopy) were analysed using both tests.
Results: "Test 2" performed better at detecting microscopy-positive blood samples when compared to "Test 1", identifying 131 of 154 positive samples (85%); 85 positives (55%) were identified using "test 1". "Test 1" produced one false positive sample (from the 20 malaria-free control) blood samples; "test 2" produced none. Kappa coefficient analysis of the results produced a value of 0.267 when microscope-positive blood smears were compared with "test 1", but 0.734 when microscope-positive blood smears were compared with the results from "test 2". Positive predictive value (PPV) and negative predictive value (NPV) were observed to be 98% and 22% respectively, for "Test 1", and 99% and 45%, for "test 2". No cross reactivity was detected with P. falciparum positive blood samples (n = 15) with either test assay.
Conclusion: Both tests detected P. vivax infected blood and showed no evidence of cross-reacting with P. falciparum. Further studies will need to be conducted to establish the full potential of this technique for malaria diagnostics. As well as representing a promising new cost-effective novel technique for P. vivax diagnosis and research, the method for developing this assay also highlights the potential for PAb-based strategies for diagnostics in general.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3913629 | PMC |
http://dx.doi.org/10.1186/1471-2334-14-49 | DOI Listing |
Porcine Health Manag
December 2024
Pig Development Department, Animal and Grassland Research and Innovation Centre, Teagasc Moorepark, P61C996, Fermoy, Co. Cork, Ireland.
Background: Oral fluid contains analytes that may be reflective of health and welfare in pig herds. Additionally, oral fluid collection is a more convenient and cost-effective option when compared to blood sampling, increasing the potential of oral fluid as a non-invasive alternative tool. While a growing number of biomarkers can be measured in porcine oral fluid, the use of these analytes to compare commercial herds in veterinary practice is still limited.
View Article and Find Full Text PDFBMC Public Health
December 2024
Muhimbili University of Health and Allied Sciences, Dar es salaam, United Republic of Tanzania.
Introduction: It is estimated that 1.3 billion people in the world have hypertension and a large proportion of them are unaware. Waist circumference has emerged as Potential predictor of Cardiovascular Diseases (CVD) risk; however, fewer studies in Tanzania have evaluated its role in screening for CVD risk.
View Article and Find Full Text PDFMicrosyst Nanoeng
December 2024
Research Center for Bionic Sensing and Intelligence, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 518055, Shenzhen, China.
We present a versatile platform for label-free magnetic separation of plasma, tailored to accommodate diverse environments. This innovative device utilizes an advanced long-short alternating double Halbach magnetic array, specifically engineered for optimal magnetic separation. The array's adaptability allows for seamless integration with separation channels of varying sizes, enabling static separation of whole blood.
View Article and Find Full Text PDFClin Lymphoma Myeloma Leuk
December 2024
Department of Hematology, University Hospital Marqués de Valdecilla/IDIVAL, Santander, Spain; University of Cantabria, Santander, Spain. Electronic address:
Multiple myeloma (MM) diagnosis requires ≥10% plasma cell (PC) infiltration in the bone marrow (BM), detected by bone marrow aspiration (BMA) or biopsy (BMB). We evaluated the concordance of these 2 techniques in 189 patients. In 43 cases (23%), the techniques were discordant, 10 due to poor sample quality.
View Article and Find Full Text PDFHipertens Riesgo Vasc
December 2024
Facultad de Ciencias Médicas, Universidad Nacional de La Plata, Argentina; Centro de Investigaciones Cardiovasculares "Dr. Horacio E. Cingolani" CONICET-UNLP, Argentina. Electronic address:
Background: Blood pressure (BP) is linearly related to the incidence of cardiovascular disease from values as low as 115/75mmHg, even at young ages. A particularly concerning issue is the decrease representation of optimal BP among children and youth. The mechanisms by which minimal elevations in BP increase cardiovascular risk are not defined.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!