A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design and implementation of an integrated magnetic spectrometer for multiplexed biosensing. | LitMetric

Magnetic spectroscopy allows for characterization of the magnetic susceptibility of magnetic beads across a broad frequency range. This enables differentiation and quantification of multiple beads of varying types concurrently present in the active volume of a sensor's surface. A magnetic spectrometer can be used for multi-probe tagging and identification akin to multi-color fluorescent bio-sensing. We propose a new sensing methodology to perform magnetic spectroscopy and analyze various important design parameters such as SNR and gain uniformity. We present a proof-of-concept design of a fully integrated CMOS magnetic spectrometer that can detect, quantify, and characterize magnetic materials in the 1.1 GHz to 3.3 GHz frequency range, where we demonstrate magnetic multiplexing capability using a mixture of two different kinds of magnetic beads. The sensor consumes less than 2 mW of DC power within the whole frequency range, requires no external biasing magnetic fields, is implemented in a standard CMOS process, and can be powered and operated completely from a USB interface. The magnetic spectrometer not only increases the throughput and multiplexing of biosensing experiments for a given sensor area, but also can enable additional applications, such as magnetic flow cytometry and signal-collocation assays of multiple probes.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBCAS.2013.2297514DOI Listing

Publication Analysis

Top Keywords

magnetic spectrometer
16
magnetic
13
frequency range
12
magnetic spectroscopy
8
magnetic beads
8
design implementation
4
implementation integrated
4
integrated magnetic
4
spectrometer
4
spectrometer multiplexed
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!