Investigation of the application of phase contrast imaging using a point X-ray source to industrial non-destructive testing.

Philos Trans A Math Phys Eng Sci

Nikon Metrology UK Ltd, Tring Business Centre, Icknield Way, Tring, Herts HP23 4JX, UK.

Published: March 2014

AI Article Synopsis

  • X-Tek Systems, a part of Nikon Metrology UK, specializes in creating advanced microfocus X-ray systems for non-destructive testing in industrial applications, with products operating at voltages of 130-450 kV.
  • The study explored phase contrast in X-ray imaging, showing that a simulation indicated a notable contrast at the boundary between a cylindrical test sample and air, which matched closely with experimental results.
  • A practical case involving an old Japanese 'magic mirror' amulet was analyzed, revealing intensity variations from phase contrast when using X-ray sources above 100 kV, demonstrating the effectiveness of this imaging technique.

Article Abstract

X-Tek Systems, a division of Nikon Metrology UK, designs, develops and manufactures microfocus X-ray radiography and computed tomography systems for industrial non-destructive testing. The range of X-ray acceleration voltages of its current standard products is 130-450 kV. It is widely known that X-ray images can be created using phase contrast formed by the natural propagation of X-rays. Simulation of the natural propagation of X-rays through a cylindrical test sample predicted a small contrast peak at the boundary between the cylinder material and air. Comparison data were obtained using an X-ray source with acceleration voltage above 100 kV. The simulation results correlated well with the experimental data. A further practical example (a 'magic mirror' amulet from an old Japanese shrine) is introduced and discussed. In this specimen, we detected intensity variation including the effect of phase contrast in the operating region above 100 kV. In summary, natural propagation phase contrast was observed in radiographic images from a standard point X-ray source with acceleration voltages exceeding 100 kV.

Download full-text PDF

Source
http://dx.doi.org/10.1098/rsta.2013.0036DOI Listing

Publication Analysis

Top Keywords

phase contrast
16
x-ray source
12
natural propagation
12
point x-ray
8
industrial non-destructive
8
non-destructive testing
8
acceleration voltages
8
propagation x-rays
8
source acceleration
8
x-ray
6

Similar Publications

Transmission electron microscopy, especially at cryogenic temperature, is largely used for studying biological macromolecular complexes. A main difficulty of TEM imaging of biological samples is the weak amplitude contrasts due to electron diffusion on light elements that compose biological organisms. Achieving high-resolution reconstructions implies therefore the acquisition of a huge number of TEM micrographs followed by a time-consuming image analysis.

View Article and Find Full Text PDF

Understanding the resistive switching (RS) behavior of oxide-based memory devices at nanoscale is crucial for advancement of high-integration density in-memory computing platforms. This study explores a comprehensive growth parameter space to address the RS behavior of pulsed-laser-deposited substoichiometric TiO (TiO) thin films in search of tailored nanoscale memristors with low-power consumption and high stability. Conductive-atomic-force-microscopy-based measurements facilitate deciphering the switching behavior at nanoscale, providing a direct avenue to understand the microstructure-property relationships.

View Article and Find Full Text PDF

Light interacts with gas bubbles in various ways, potentially leading to photon losses in gas-liquid photochemical applications. Given that light is a valuable 'reagent', understanding these losses is crucial for optimizing reactor efficiency. In this study, we address the challenge of quantifying these interactions by implementing a method that separately determines the photon flux and utilizes actinometric experiments to determine the effective optical path length, a key descriptor of photon absorption.

View Article and Find Full Text PDF

Introduction: Reports of pseudoaneurysms associated with biliary self-expandable metallic stent (SEMS) placement have been increasing. Recently, cases of hepatic pseudoaneurysm rupture caused by double pigtail plastic stents (DPS) have also been reported. The symptoms of pseudoaneurysms are often non-specific, and many cases are diagnosed only after rupture.

View Article and Find Full Text PDF

A 50-year-old patient with a prior history of chronic smoking presented to the emergency department with diffuse abdominal pain, primarily localized to the right hypochondrium and epigastric region, along with nausea, but without fever, vomiting, or urinary symptoms. Laboratory tests were largely unremarkable except for isolated hematuria and a mildly elevated CRP. Given the atypical clinical presentation, a 3-phase abdominal CT scan (without contrast, portal, and delayed phases) was conducted, revealing a horseshoe kidney with an obstructing 4 mm stone at the right ureteral meatus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!