Inadvertent migration of central venous catheters can lead to several issues including delayed therapy and clinical morbidities such as thrombosis. Peripherally inserted central catheters (PICCs) are particularly at risk of movement. An innovative new device which allows anchorage of the catheter has proved very successful in the minimisation of catheter migration. The SecurAcath device incorporates a small blunt anchor which lies beneath the skin in order to secure the catheter in place and prevent inadvertent movement. An evaluation of 31 patients with a SecurAcath device in situ to secure a PICC found only one case of insignificant catheter migration. Some initial problems with infection and pain were encountered and interventions were put in place to minimise their incidence. SecurAcath removal proved to be the most significant challenge but this can be overcome with suitable guidance and training.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.12968/bjon.2014.23.sup1.s12 | DOI Listing |
J Med Case Rep
January 2025
Department of Orthopedic Surgery, Graduate School of Medicine, Kanazawa University, 13-1 Takara-machi, Kanazawa City, Ishikawa, 920-8641, Japan.
Background: Intrathecal baclofen therapy can substantially improve symptoms in patients with severe spasticity owing to traumatic spinal cord injury, multiple sclerosis, cerebral paresis, or tethered cord syndrome. Problems associated with intrathecal catheters include migration, laceration, occlusion, or disconnection. Several case reports have described the management of catheter fragments.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Mexico City, Mexico.
The use of the snare catheter (SC) technique has been described in the field of interventional cardiology, in particular in the retrieval of a lost device, for example, a dislodged coronary stent, broken coronary wire, and so forth. In the transcatheter aortic valve replacement (TAVR) procedure, some cases have been observed where the anatomy is challenging or there are scenarios where some complications occur during the procedure, which make it necessary to use some tools to achieve the success of the procedure. The SC has shown are very useful either to achieve the ascent of the valve to the annular plane in complex anatomies or as a rescue measure in the event of complications that may arise after valve implantation.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
January 2025
Department of Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada; Sunnybrook Research Institute, Toronto, Canada.
The integration of self-expandable nitinol frames with cable-driven parallel mechanisms offers a promising advancement in minimally invasive cardiovascular interventions. This study presents the design, fabrication, and verification of a miniaturized self-expandable nitinol frame to enhance catheter tip steerability and navigation within complex vascular anatomies. The frame is reduced in size for delivery through 7-8 Fr sheaths while accommodating diverse vascular diameters, allowing up to a maximum expansion of 15 mm.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość, 22-400 Zamosc, Poland.
Removal of spontaneously fractured leads with their proximal ends migrated into the vascular space has not been analysed in detail thus far. The study aimed to compare the effectiveness of different approaches and auxiliary tools for removing fractured leads with migrated proximal ends. Retrospective analysis of 72 cases from a database containing 3847 TLEs (transvenous lead extraction).
View Article and Find Full Text PDFUrology
January 2025
Department of Urologic Oncology, Barretos Cancer Hospital, Barretos, São Paulo, Brazil. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!