Background: Echocardiography-guided (EG) left ventricular (LV) lead placement at the site of latest mechanical activation improves outcome in heart failure (HF) patients receiving a cardiac resynchronization therapy (CRT)-defibrillator (CRT-D).

Objective: The purpose of this study was to examine the effect of a strategy of EG LV lead placement in each of ischemic (ICM) vs nonischemic (NICM) cardiomyopathy patients.

Methods: Patients enrolled in the Speckle Tracking Assisted Resynchronization Therapy for Electrode Region (STARTER) prospective, randomized trial who were treated with a CRT-D device (108 EG strategy and 75 routine strategy) were followed to the end-points of death, appropriate CRT-D therapy, or HF hospitalization.

Results: Of the patients enrolled in STARTER, 115 had ICM and 68 had NICM. Over mean follow-up of 3.7 ± 2.1 years, 62 patients died, 40 received appropriate CRT-D therapy, and 67 had HF hospitalizations. Compared to NICM patients, patients with ICM had worse survival (P = .0003), worse survival free from implantable cardioverter-defibrillator therapy (P = .004), and survival free from HF hospitalization (P = .0001). A strategy of EG LV lead placement improved the outcome of CRT-D therapy-free survival primarily in ICM patients and the outcome of HF hospitalization-free survival in both ICM and NICM patients. Achieving LV resynchronization was most critical in ICM patients in whom arrhythmic and HF outcomes improve with resynchronization to levels comparable to those of NICM patients.

Conclusion: A strategy of EG LV lead placement improves HF-free survival equally in ICM and NICM patients and CRT-D therapy-free survival more favorably in ICM patients to levels comparable to those of NICM patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2014.01.023DOI Listing

Publication Analysis

Top Keywords

lead placement
20
nicm patients
16
patients
13
resynchronization therapy
12
strategy lead
12
icm nicm
12
icm patients
12
echocardiography-guided left
8
left ventricular
8
ventricular lead
8

Similar Publications

Purpose: We aimed to determine whether implementation of clinical decision support (CDS) tool integrated into the electronic health record (EHR) of a multi-site academic medical center increased the proportion of patients with American Urological Association (AUA) "high risk" microscopic hematuria (MH) who receive guideline concordant evaluations.

Materials And Methods: We conducted a two-arm cluster randomized quality improvement project in which 202 ambulatory sites from a large health system were randomized to either have their physicians receive at time of test results an automated CDS alert for patients with 'high-risk' MH with associated recommendations for imaging and cystoscopy (intervention) or usual care (control). Primary outcome was met if a patient underwent both imaging and cystoscopy within 180 days from MH result.

View Article and Find Full Text PDF

Background: Rising antimicrobial resistance (AMR) is an acute public health emergency impeding the clinical efficacy of surgical interventions. Biliary stent placement is one of the routine surgical procedures that rarely lead to infections that are empirically managed by broad-spectrum β-lactams and fluoroquinolones. Critical priority pathogens, such as carbapenem-resistant Escherichia coli challenge treatment outcomes and infection prevention.

View Article and Find Full Text PDF

Beta-tricalcium phosphate patient-specific gap implants in bilateral sagittal split osteotomy: an innovative treatment method to enhance the mandibular border contour. Part 1: concept and workflow.

Int J Oral Maxillofac Surg

January 2025

Division of Maxillofacial Surgery, Department of Surgery, AZ Sint-Jan Brugge AV, Bruges, Belgium; Oral and Maxillofacial Surgery Unit, Division of Surgery, Barzilai Medical Center, Affiliated to Ben-Gurion University of the Negev, Ashkelon, Israel.

Antegonial notching can occur after bilateral sagittal split osteotomy (BSSO) and may lead to unpleasant aesthetic outcomes in both young and older patients. This clinical study presents a new concept to potentially overcome this problem and describes the workflow. Beta-tricalcium phosphate patient-specific gap implants (β-TCP gap-PSIs) are biocompatible and resorbable bone grafts that are placed in the space of the osteotomy gap during orthognathic procedures; they are virtually planned and printed in 3D.

View Article and Find Full Text PDF

Purpose: Trabecular micro-bypass devices (TBDs) such as the iStent series (Glaukos Corporation, Laguna Hills, CA), are effective in reducing intraocular pressure (IOP). However, precise placement of TBDs is crucial in achieving surgical efficacy, as device malpositioning may lead to suboptimal IOP reduction. We demonstrate two novel intra-operative signs to aid confirmation of accurate iStent placement, without reliance on imaging technologies.

View Article and Find Full Text PDF

We present a case of an 80-year-old female who presented with chest pain, vomiting and night sweats a few weeks post thoracic endovascular aortic aneurysm repair (TEVAR). A computed tomography (CT) scan demonstrated a type 1B endoleak for which she underwent a repeat TEVAR. Postoperatively, she developed fever, dysphagia, haematemesis and melaena.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!