Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Independent monitor unit verification calculation (MUVC) has been recommended by several authors for intensity modulated radiotherapy (IMRT) as a patient specific quality assurance tool. Aim of the present work is to develop an in-house excel spread sheet based MUVC program for volumetric modulated arc therapy (VMAT) using Clarkson's integration technique. Total scatter factor (S(c,p)) and tissue maximum ratio (TMR) for circular fields obtained from Treatment planning system (TPS) were used for the calculation. Multileaf collimator (MLC) interleaf leakage, MLC round edge transmission and tongue and groove effect were accounted. MUVC calculation was performed for 58 patients both for patient anatomy and for homogenous cylindrical phantom. Radiological path lengths were used as water equivalent depths (WED) for calculations using patient anatomy. Monitor unit (MU) discrepancies between -2.60% and 0.28% with mean deviation of -0.92% ± 0.75% were obtained for homogenous cylindrical phantom calculations. MUVC for patient anatomy resulted in large variations between -19.02% and 0.67% for 14 plans where isocenter was at a region below -350 HU. But For 44 plans where the isocenter was at a region above -350 HU, variations between -3.44% and 0.48% were obtained with mean deviation of -1.73% ± 1.12%. For VMAT patient specific quality assurance, the independent MUVC algorithm can be used as an easy and quick auxiliary to measurement based verification for plans with isocenter at a region above -350 HU.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejmp.2014.01.001 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!