A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In-house spread sheet based monitor unit verification program for volumetric modulated arc therapy. | LitMetric

Independent monitor unit verification calculation (MUVC) has been recommended by several authors for intensity modulated radiotherapy (IMRT) as a patient specific quality assurance tool. Aim of the present work is to develop an in-house excel spread sheet based MUVC program for volumetric modulated arc therapy (VMAT) using Clarkson's integration technique. Total scatter factor (S(c,p)) and tissue maximum ratio (TMR) for circular fields obtained from Treatment planning system (TPS) were used for the calculation. Multileaf collimator (MLC) interleaf leakage, MLC round edge transmission and tongue and groove effect were accounted. MUVC calculation was performed for 58 patients both for patient anatomy and for homogenous cylindrical phantom. Radiological path lengths were used as water equivalent depths (WED) for calculations using patient anatomy. Monitor unit (MU) discrepancies between -2.60% and 0.28% with mean deviation of -0.92% ± 0.75% were obtained for homogenous cylindrical phantom calculations. MUVC for patient anatomy resulted in large variations between -19.02% and 0.67% for 14 plans where isocenter was at a region below -350 HU. But For 44 plans where the isocenter was at a region above -350 HU, variations between -3.44% and 0.48% were obtained with mean deviation of -1.73% ± 1.12%. For VMAT patient specific quality assurance, the independent MUVC algorithm can be used as an easy and quick auxiliary to measurement based verification for plans with isocenter at a region above -350 HU.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2014.01.001DOI Listing

Publication Analysis

Top Keywords

monitor unit
12
patient anatomy
12
plans isocenter
12
isocenter region
12
region -350
12
spread sheet
8
sheet based
8
unit verification
8
program volumetric
8
volumetric modulated
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!