Movement of impression copings inside the impression material using a direct (open tray) impression technique during clinical and laboratory phases may cause inaccuracy in transferring the 3-dimensional spatial orientation of implants intraorally to the cast. Consequently, the prosthesis may require corrective procedures. This in vitro study evaluated the accuracy of 3 different impression techniques using polyether and vinyl polysiloxane (VPS) impression material to obtain a precise cast for multiple internal connection implants. A reference acrylic resin model with 4 internal connection implants was fabricated. Impressions of the reference model were made using 3 different techniques and 2 different impression materials. The study consisted of 24 specimens divided into 6 groups of 4 each. Impressions were poured with ADA type IV stone (Kalrock, Kalabhai Karson Pvt Ltd, Mumbai, India). All casts were evaluated for the positional accuracy (mm) of the implant replica heads using a profile projector. These measurements were compared to the measurements calculated on the reference resin model, which served as a control. Data were analyzed with 2-way analysis of variance (ANOVA) followed by Bonferroni multiple comparison procedures to evaluate group means. The results revealed significant difference for anterior implant distance between the 2 impression materials (P < .01) and also among the 3 different techniques (P < .05). The lowest mean variation was found with the polyether impression material and the splinted technique. For posterior implants, the results suggested no significant difference between the 2 impression materials (P ≥ .05). Although results were not statistically significant, the polyether impression material showed the lowest mean variation as compared to the VPS impression material. However, there was a significant difference among the 3 different techniques (P < .05). Among the 3 different techniques, the lowest mean variation between 2 posterior implants was found in the splinted technique. Casts obtained from impression techniques using square impression copings splinted together with autopolymerizing acrylic resin prior to the impression procedure were more accurate than casts obtained from impressions with nonmodified implant impression copings and with airborne particle-abraded, adhesive-coated copings. Casts obtained from polyether impression material were more accurate than casts obtained from vinyl polysiloxane impression material.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1563/AAID-JOI-D-10-00207 | DOI Listing |
BMC Oral Health
December 2024
Faculty of Odonto-Stomatology, University of Health Sciences, Vietnam National University Ho Chi Minh City, Ho Chi Minh City, Vietnam.
Background: The success of a restoration largely depends on the quality of its fit. This study aimed to investigate the fit quality of monolithic zirconia veneers (MZVs) produced through traditional and digital workflows.
Methods: A typodont maxillary right central incisor was prepared.
Zh Nevrol Psikhiatr Im S S Korsakova
December 2024
GUTA-CLINIC LLC, Moscow, Russia.
Objective: Evaluation of the safety and effectiveness of Relatox, botulinum toxin type A in patients with focal spasticity (FS) of the upper limb as a result of a cerebrovascular accident (CVA) or traumatic brain injury (TBI).
Material And Methods: A multicenter, prospective, single-blinded, randomized, comparative clinical study included 210 patients of both sexes aged 18-75 years after moderate to severe TBI and CVA in seven sites in the Russian Federation. The patients were randomized into two groups.
CNS Drugs
December 2024
Pediatric Neurology Division, Department of Pediatrics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India.
Background And Objectives: Ecopipam is a selective antagonist of the dopamine D1 receptor, and its efficacy and safety have recently been explored in several clinical trials involving patients with Tourette syndrome (TS). The objectives of this systematic review were to determine the pooled estimate for efficacy [in terms of reduction in tic Yale Global Tic Severity Scale (YGTSS) scores] and safety of oral ecopipam in subjects with TS.
Methods: All clinical trials that explored the efficacy and/or safety of ecopipam in patients with TS were included to determine the pooled estimate for change in YGTSS, Clinical Global Impression (CGI)-TS, and the severity of comorbid attention-deficit hyperactive disorder (ADHD), obsessive compulsion disorder (OCD), and depressive symptoms, as well as the nature and frequency of adverse effects.
J Funct Biomater
December 2024
Centre for Oral Rehabilitation, Linköping, County Council of Östergötland, 581 86 Linköping, Sweden.
Objective: This study aimed to assess and compare the internal fit of custom-made posts and cores fabricated using digital impressions (DI) and conventional vinyl polysiloxane (VPS) impressions in restorative dentistry.
Materials And Methods: A typodont tooth model, simulating the anatomy of the root canal of a central incisor, was utilized for the study. Two groups were formed, Group A and Group B, and each group provided a total of 18 impressions of two types: DIs and VPS impressions.
Dent J (Basel)
November 2024
Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, MA 02115, USA.
Occlusion plays a crucial role in the long-term success and functionality of dental restorations. The purpose of this study was to investigate the changes in occlusal contacts upon the cementation of zirconia crowns with different cement spacer settings in computer-aided design and computer-aided manufacturing (CAD-CAM) software (3Shape Dental System version 2.102.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!