A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A dosimetry method for low dose rate brachytherapy by EGS5 combined with regression to reflect source strength shortage. | LitMetric

The post-implantation dosimetry for brachytherapy using Monte Carlo calculation by EGS5 code combined with the source strength regression was investigated with respect to its validity. In this method, the source strength for the EGS5 calculation was adjusted with the regression, so that the calculation would reproduce the dose monitored with the glass rod dosimeters (GRDs) on a water phantom. The experiments were performed, simulating the case where one of two (125)I sources of Oncoseed 6711 was lacking strength by 4-48%. As a result, the calculation without regression was in agreement with the GRD measurement within 26-62%. In this case, the shortage in strength of a source was neglected. By the regression, in order to reflect the strength shortage, the agreement was improved up to 17-24%. This agreement was also comparable with accuracy of the dose calculation for single source geometry reported previously. These results suggest the validity of the dosimetry method proposed in this study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4014170PMC
http://dx.doi.org/10.1093/jrr/rrt147DOI Listing

Publication Analysis

Top Keywords

source strength
12
dosimetry method
8
strength shortage
8
strength
6
regression
5
source
5
calculation
5
method low
4
low dose
4
dose rate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!