A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of simulated cone beam computed tomography to conventional helical computed tomography for imaging of rhinosinusitis. | LitMetric

Objectives/hypothesis: Cone beam computed tomography (CBCT) has emerged as a low radiation dose alternative to traditional computed tomography (CT) to evaluate the paranasal sinuses. The purpose of our study was to determine how often clinically important findings would be missed if CBCT was used routinely for sinus imaging.

Study Design: Retrospective review.

Methods: We evaluated all maxillofacial CT scans performed for sinusitis over a 1-year period. The original multidetector CT (MDCT) images were reviewed retrospectively. A theoretical CBCT was then created from the original study utilizing only the bone algorithm images and separately reviewed. We calculated the proportion of abnormal findings that were identified on the MDCT but would have been missed by the theoretical CBCT, and reviewed the medical record to determine which potentially missed findings would have changed management. Radiation dose from the MDCT scanners was calculated and compared to published dose estimates for the paranasal sinuses on CBCT.

Results: Maxillofacial CTs from 361 consecutive patients were included, of which 12 (3.3%) demonstrated findings that would have been missed on the theoretical CBCT. Of those, four (1.1%) would have resulted in a change in management. Effective radiation dose for our scanners ranged from 0.67 mSv to 2.15 mSv, compared to a published estimated dose of 0.2 mSV for CBCT.

Conclusions: In the majority of patients undergoing simulated CBCT for evaluation of sinusitis, incidental findings of soft-tissue disease were rare. With appropriate selection of patients, CBCT can offer substantial radiation dose reduction and may provide a viable alternative to standard MDCT sinus imaging protocols.

Download full-text PDF

Source
http://dx.doi.org/10.1002/lary.24603DOI Listing

Publication Analysis

Top Keywords

computed tomography
16
radiation dose
16
theoretical cbct
12
cone beam
8
beam computed
8
paranasal sinuses
8
findings missed
8
missed theoretical
8
compared published
8
cbct
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!