Objective: The effect of levosimendan on renal function in patients with low ejection fraction undergoing mitral valve surgery was investigated.

Design: A prospective, double-blinded, randomized clinical trial.

Setting: Tertiary teaching and research hospital.

Participants: Of a total of 147 patients, 128 patients completed the study. In the levosimendan group (n = 64), levosimendan was administered in addition to standard inotropic support; whereas, in the control group (n = 64), only standard inotropic support was given.

Interventions: In the levosimendan group, a loading dose of levosimendan (6 μg/kg) was administered after removal of the aortic cross-clamp, followed by an infusion (0.1 μg/kg/min) in addition to standard inotropic therapy for 24 hours. In the control group, only standard inotropic therapy was administered. Preoperative characteristics, serum creatinine (sCr) levels, and estimated glomerular filtration rate (eGFR) were determined preoperatively, on postoperative days 1, 3, and 10. Independent risk factors for renal replacement therapy (RRT) requirement were investigated with stepwise multivariate logistic regression analysis.

Measurements And Main Results: The primary endpoint was the effect of levosimendan on postoperative renal clearance (sCr and eGFR). The secondary endpoint was the effect of levosimendan on clinical outcomes (length of intensive care unit and hospital stays, need for RRT). Preoperative characteristics and eGFR were similar between the groups (p>0.05). On postoperative days 1 and 3, sCr values were lower and eGFR values were higher in the levosimendan group in comparison with the control group (p = 0.0001, p = 0.009, respectively). Six patients (9.4%) in the levosimendan group and 10 patients (15.6%) in the control group required RRT therapy (p = 0.284). Independent risk factors for need of RRT include preoperative sCr value between 1.2 to 2.09 mg/dL and≥2.1 mg/dL (p< 0.05).

Conclusions: Perioperative treatment with levosimendan in addition to standard inotropic therapy in patients with a low ejection fraction undergoing mitral valve surgery improved immediate postoperative renal function and reduced need for RRT.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2013.09.004DOI Listing

Publication Analysis

Top Keywords

standard inotropic
20
levosimendan group
16
control group
16
addition standard
12
inotropic therapy
12
levosimendan
11
renal function
8
patients low
8
low ejection
8
ejection fraction
8

Similar Publications

Introduction: One of the most prevalent healthcare-associated infections in the pediatric intensive care unit is ventilator-associated pneumonia (VAP). VAP not only results in prolonged hospital and intensive care unit (ICU) stays but also imposes higher costs on patients and the healthcare system. Therefore, it is essential to implement preventive measures.

View Article and Find Full Text PDF

Objective: Accurate measurement of pelvic floor muscle (PFM) strength is crucial for the management of pelvic floor disorders. However, the current methods are invasive, uncomfortable, and lack standardization. This study aimed to introduce a novel noninvasive approach for precise PFM strength quantification by leveraging extracorporeal surface perineal pressure (ESPP) measurements and machine learning algorithms.

View Article and Find Full Text PDF

Hospital Variability in the Use of Vasoactive Agents in Patients Hospitalized for Acute Decompensated Heart Failure for Clinical Phenotypes.

Circ Cardiovasc Qual Outcomes

January 2025

Tokyo Cardiovascular Care Unit Network Scientific Committee, Japan (Y.S., N.N., S. Kohsaka, K.H., T.K., M. Takei, T.J., H.N., J.M., A.S., D.K., S.T., S. Koba, T.Y., M. Takayama).

Background: The absence of practice standards in vasoactive agent usage for acute decompensated heart failure has resulted in significant treatment variability across hospitals, potentially affecting patient outcomes. This study aimed to assess temporal trends and institutional differences in vasodilator and inotrope/vasopressor utilization among patients with acute decompensated heart failure, considering their clinical phenotypes.

Methods: Data were extracted from a government-funded multicenter registry covering the Tokyo metropolitan area, comprising consecutive patients hospitalized in intensive/cardiovascular care units with a primary diagnosis of acute decompensated heart failure between January 2013 and December 2021.

View Article and Find Full Text PDF

The Potential of Neonatal Organ Donation in Central Sweden.

Cell Transplant

January 2025

Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden.

Pediatric organ transplant recipients have a higher risk for wait list mortality due to the scarcity of size matched organs. Neonatal organ donation could potentially ameliorate the discrepancy but is currently not implemented in Sweden. This study aims to evaluate the potential of neonatal organ donation in central Sweden using a standardized protocol with organ specific criteria.

View Article and Find Full Text PDF

BACKGROUND Extracorporeal blood purification strategies were recently developed as adjunctive treatments for sepsis. CytoSorb® is an approved medical device designed to reduce blood levels of inflammatory cytokines. The oXiris high-adsorption membrane filter is used in continuous hemofiltration adsorption.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!