The dielectric (DE) properties, specifically the DE constant (ε') and loss factor (ε''), were measured for vacuum-dried and freeze-dried potato samples at a microwave frequency of 2.45 GHz over a range of different moisture contents (MCs) using a DE probe and also a 2-probe electrochemical impedance spectroscopy (EIS). Third-order polynomial models (ε' = f₁(MC); and ε'' = f₂(MC)) at room temperature were developed for regression analysis. Additionally, at various temperatures (T), biphasic 3rd-order polynomial models (ε' = f₁(MC, T); and ε'' = f₂(MC, T)) were obtained to determine ε' and ε'' as a function of MC and T using measured data. The vacuum-dried potato sample showed a good fitness of ε' and ε'' (R² = 0.95 and 0.96, respectively) to the regression model with the range of MCs from 18% to 80% (w/w), while the freeze-dried potato sample showed a good fitness of ε' and ε'' to the 1st-phase regression model with MC < 50% w/w (R² = 0.95 and 0.96, respectively) and the 2nd-phase regression model with MC > 50% w/w (R² = 0.94 to 0.96). EIS measurements were also used to obtain correlation impedances for ε' and ε'' determined by the DE probe method. The resulted regression analysis meets the demands for simple, rapid, and accurate assessment for transient values of ε' and ε'' of food products during dehydration/drying processes. The EIS method was verified to be a successful alternative to direct measurements of ε' and ε''.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/1750-3841.12335 | DOI Listing |
Prostate Cancer
April 2020
Department of Electrical Engineering, Eindhoven University of Technology, De Rondom 70, 5612 AP, Eindhoven, Netherlands.
Objective: To compare prostate cancer detection rates (CDRs) and pathology results with targeted prostate biopsy (TB) and systematic prostate biopsy (SB) in biopsy-naive men.
Methods: An in-patient control study of 82 men undergoing SB and subsequent TB in case of positive prostate MRI between 2015 and 2017 in the Jeroen Bosch Hospital, the Netherlands.
Results: Prostate cancer (PCa) was detected in 54.
BMC Urol
April 2019
Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Background: To overcome the limitations regarding two dimensional (2D) greyscale (GS) transrectal ultrasound (TRUS)-guided biopsy in prostate cancer (PCa) detection and tissue packaging in biopsy processing, there is an ongoing focus on new imaging and pathology techniques. A three-dimensional (3D) model of the prostate with biopsy needle guidance can be generate by the Navigo™ workstation (UC-care, Israel). The SmartBX™ system (UC-care, Israel) provides a prostate biopsy core preembedding method.
View Article and Find Full Text PDFWorld J Urol
June 2018
Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Purpose: To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens.
Methods: Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!