Purpose: To assess the effect of body mass index (BMI) on dose to organs at risk (OARs) during high-dose-rate vaginal brachytherapy and evaluate the role of three-dimensional dose evaluation during treatment planning.
Methods And Materials: Three-dimensional dosimetric data for rectum, bladder, sigmoid colon, and small bowel for 125 high-dose-rate vaginal brachytherapy fractions were analyzed. Dose-volume histograms were generated for D0.1 cc and D2 cc of each OAR. Contributing factors including the use of urinary catheter and cylinder size were also recorded. As different dose fractionations were used, the OAR doses were tabulated as a percent dose prescribed to 0.5cm. All patients were treated to 4cm of the vaginal length.
Results: Median BMI in this cohort was 31.7kg/m(2). The BMI values had a weak inverse correlation with D0.1 cc to sigmoid colon (rs=-0.18, p=0.047) and D0.1 cc to bladder (rs=-0.19, p=0.038). There was a strong inverse correlation of D2 cc and increasing BMI (rs=-0.64, p=0.003). The median D2 cc was 25.1% for BMI higher than 31 and 61.9% for BMI of 31 or lower. For D0.1 cc, there was also a strong inverse correlation with increasing BMI (rs=-0.57, p<0.001). Median D1 cc was 33.5% for BMI >31 and 84.4% for BMI ≤ 31. On multivariate analysis higher BMI remained a significant predictor of lower small bowel D2 cc (p<0.001) and D0.1 cc (p<0.001).
Conclusions: Women with a lower BMI receive higher doses to the bladder and small bowel compared with those with a higher BMI. Three-dimensional dose evaluation should be considered in patients with low BMI, particularly when combined with external beam radiation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4532275 | PMC |
http://dx.doi.org/10.1016/j.brachy.2013.12.002 | DOI Listing |
J Gynecol Oncol
November 2024
The 3th Ward of Radiotherapy Department, Guangzhou Institute of Cancer Research, The Affiliated Cancer Hospital, Guangzhou Medical University, Guangzhou, China.
Objective: To explore the application value of using 3-dimensional (3D) printing (3DP) technology to create individualized vaginal molds for brachytherapy (BT) in high-dose-rate 3D cervical cancer through reverse engineering of needle placement.
Methods: Prospectively, 11 patients with cervical cancer were treated with 3DP-intracavitary/interstitial (IC/IS) BT using 3DP to create individualized vaginal molds. All patients were performed BT after completion of external beam radiotherapy (EBRT).
J Contemp Brachytherapy
October 2024
Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, Changchun 130033, China.
Purpose: To present an innovative deformable applicator that used Freiburg flap as vaginal applicator with or without free-hand interstitial needles in three-dimensional (3D) high-dose-rate (HDR) brachytherapy for vaginal stump recurrence of cervical cancer.
Material And Methods: Between September 2017 and January 2020, all patients with vaginal stump recurrence after radical hysterectomy of cervical cancer treated with vaginal stump brachytherapy using Freiburg flap as vaginal applicator with or without free-hand interstitial needles were retrospective analyzed. Characteristics related to patients and treatment modality as well as preliminary outcomes and side effects were investigated.
J Contemp Brachytherapy
October 2024
Radiotherapy Department, Hospital Clínica Benidorm, Benidorm, Alicante, Spain.
Purpose: The purpose of the study was to analyze patients with vaginal-involving recurrences of gynecological tumors and primary vaginal tumors, treated with transperineal interstitial brachytherapy (P-ISBT). Dosimetric, clinical, and toxicity analysis of these patients was conducted, incorporating MRI in volume definition and dose-volume dosimetry.
Material And Methods: Forty-two patients were retrospectively analyzed.
J Contemp Brachytherapy
October 2024
Radiation Oncology, Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum University of Bologna, Bologna, Italy.
Purpose: This systematic review aimed to assess the feasibility, safety, and efficacy of using modern external beam radiotherapy (EBRT) techniques, such as intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic body radiotherapy (SBRT) as alternative approaches to brachytherapy (BRT) in adjuvant treatment of endometrial cancer (EC).
Material And Methods: A systematic review was conducted following PRISMA guidelines. The research question was framed using the PICO method, focusing on patients with EC [P] and comparing modern EBRT techniques (IMRT, VMAT, SBRT) [I] vs.
J Contemp Brachytherapy
October 2024
Fonaments Clinics Department, Universitat de Barcelona, Barcelona, Spain.
Purpose: Currently, there are many schedules for exclusive vaginal cuff brachytherapy (VCB). In 3D treatment planning for VCB dosimetry, parameters have not been analyzed. The aim of this study was to compare the most common schedules using dose-volume histogram metrics.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!